* Modbus: remove legacy code
flexit and stiebel_el are updated to import modbus.const,
therefore legacy code can be removed.
* Flexit: update const reference from modbus
climate.py imports from modbus direct, this is legacy and will
result in errors.
update import to be modbus.const.
* Stiebel_el: update reference to modbus
__init.py references modbus directly, this is legacy and will
give errors.
Update import to be modbus.const.
* Use new labels for HomematicIP Cloud multi devices
* Update homeassistant/components/homematicip_cloud/device.py
Co-Authored-By: springstan <46536646+springstan@users.noreply.github.com>
* Update name composition
Co-authored-by: springstan <46536646+springstan@users.noreply.github.com>
* modbus: bumb pymodbus version to 2.3.0
pymodbus version 1.5.2 did not support asyncio, and in general
the async handling have been improved a lot in version 2.3.0.
updated core/requirement*txt
* updated core/CODEOWNERS
committing result of 'python3 -m script.hassfest'.
* modbus: change core connection to async
change setup() --> async_setup and update() --> async_update()
Use async_setup_platform() to complete the async connection to core.
listen for EVENT_HOMEASSISTANT_START happens in async_setup()
so it needs to be async_listen.
But listen for EVENT_HOMEASSISTANT_STOP happens in start_modbus()
which is a sync. function so it continues to be listen().
* modbus: move setup of pymodbus into modbushub
setup of pymodbus is logically connected to the class modbushub,
therefore move it into the class.
Delay construction of pymodbus client until event
EVENT_HOMEASSISTANT_START arrives.
* modbus: use pymodbus async library
convert pymodbus calls to refer to the async library.
Remark: connect() is no longer needed, it is done when constructing
the client. There are also automatic reconnect.
* modbus: use async update for read/write
Use async functions for read/write from pymodbus.
change thread.Lock() to asyncio.Lock()
* Modbus: patch for slow tcp equipment
When connecting, via Modbus-TCP, so some equipment (like the
huawei sun2000 inverter), they need time to prepare the protocol.
Solution is to add a asyncio.sleep(x) after the connect() and before
sending the first message.
Add optional parameter "delay" to Modbus configuration.
Default is 0, which means do not execute asyncio.sleep().
* Modbus: silence pylint false positive
pylint does not accept that a class construction __new__
can return a tuple.
* Modbus: move constants to const.py
Create const.py with constants only used in
the modbus integration.
Duplicate entries are removed, but NOT any entry that would
lead to a configuration change.
Some entries were the same but with different names, in this
case renaming is done.
Also correct the tests.
* Modbus: move connection error handling to ModbusHub
Connection error handling depends on the hub, not the
entity, therefore it is logical to have the handling in
ModbusHub.
All pymodbus call are added to 2 generic functions (read/write)
in order not to duplicate the error handling code.
Added property "available" to signal if the hub is connected.
* Modbus: CI cleanup
Solve CI problems.
* Modbus: remove close of client
close() no longer exist in the pymodbus library, use
del client instead.
* Modbus: correct review comments
Adjust code based on review comments.
* Modbus: remove twister dependency
Pymodbus in asyncio mode do not use twister but still throws a
warning if twister is not installed, this warning goes into
homeassistant.log and can thus cause confusion among users.
However installing twister just to avoid the warning is not
the best solution, therefore removing dependency on twister.
* Modbus: review, remove comments.
remove commented out code.
* Plum Lightpad - glowIntensity is represented as a float/percentage
Calculate brightness from the glowIntensity instead of the glowIntensity from brightness.
* Renamed `_glowIntensity` to `_glow_intensity`
* Added Rounding, converting to an int, min and max boxing
* Added codeowners to the Plum Lightpad manifest.json
This upgrades to PyVicare 0.1.10 which allows to combine multiple
requests into a single HTTP GET. This in turn allows us to increase
the scan_interval to 60 seconds by default.
Additionally scan_interval has been introduced as a config parameter.
When in run schedule mode, setting the temperature will switch
the device to a temporary hold. If you set the temperature
again, we should stay in temporary hold mode and not switch
to permanent hold.
The underlying nuheat package contains a default to a
permanent hold if no setting was passed. We now always
pass the setting.
* Implement Alexa.CameraStreamController.
* Add dependencies.
* Add camera helpers for image url, and mjpeg url.
* Remove unsupported AlexaPowerController from cameras.
* Refactor camera_stream_url to hass_url
* Declare HLS instead of RTSP.
* Add test for async_get_image_url() and async_get_mpeg_stream_url().
* Sort imports.
* Fix camera.options to camera.stream_options. (#32767)
(cherry picked from commit 9af95e8577)
* Remove URL configuration option for AlexaCameraStreamController.
* Update test_initialize_camera_stream.
* Optimize camera stream configuration.
* Update Tests for optimized camera stream configuration.
* Sort imports.
* Add check for Stream integration.
* Checks and Balances.
* Remove unnecessary camera helpers.
* Return None instead of empty list for camera_stream_configurations().
In PR#24804 the step size was changed to match the step size
of the device that HomeKit is controlling. Since HomeKit
is always working in TEMP_CELSIUS and the step size is based on
the Home Assistant units setting, we were mixing data with different
units of measure when Home Assistant was using imperial units.
This regression presented the symptom that setting the
temperature to 73F would result in 74F. Other values are affected
where the math doesn't happen to work out.
HomeKit currently has a default of 0.1 in the spec and the override
of this value has been removed.
* Config flow for elkm1
* As entity ids can now be changed, the “alarm_control_panel”
attribute “changed_by_entity_id” is now “changed_by_keypad”
and will show the name of the Elk keypad instead of the entity id.
* An auto configure mode has been introduced which avoids the
need to setup the complex include and exclude filters. This
functionality still exists when configuring from yaml for power
users who want more control over which entities elkm1 generates.
* restore _has_all_unique_prefixes
* preserve legacy behavior of creating alarm_control_panels that have no linked keypads when auto_configure is False
* unroll loop
* Add integration for Schluter
New integration for Schluter DITRA-HEAT thermostats. Interacts with Schluter API via py-schluter to implement climate platform.
* Fix for manifest issue on build
Removed unnecessary configurator logic
* Flake8 & ISort issues fixed
* Code review modifications for Schluter integration
- Removed unnecessary strings.json file
- Removed unnecessary DEFAULT_SCAN_INTERVAL from __init__.py
- Removed persistent notification for authentication error in __init__.py
- Removed string casts from log statements in __init__.py
- Removed unnecessary logging of entity creations in climate.py
- Removed unnecessary lookup for hvac_mode in climate.py
* Work started on Update Coordinator
* Further Coordinator work
* Update to DataUpdateCoordinator complete
* Flake8 fix
* Removal of unnecessary SchluterPlatformData
Coordinator also now using SCAN_INTERVAL
* Disable polling, use coordinator listeners
* Isort on climate.py
* Code review modifications
- Hass data stored under domain
- Since platform only likely to be climate, removed array, load explicitly
- Remove unnecessary fan mode implementation
* Switch to HVAC action for showing current heating status
* Isort fix
* HVAC Mode return list, set_hvac_mode function added
* __init__.py modifications from code review
* Climate.py code review modifications
- Device info property removed
- Write state function on set temp failure
- Add "available" property
- Delegate sync function in coordinator update to the executor
* Serial number as unique identifier
- Now using serial number & thermostat dictionary to protect against scenarios where a device is removed and enumerable index is no longer accurate
- Removed async_write_ha_state() from set temp exception, not needed
- Removed unnecessary SCAN_INTERVAL definition
* Linting
* Update homeassistant/components/schluter/climate.py
Co-Authored-By: Paulus Schoutsen <paulus@home-assistant.io>
* Update homeassistant/components/schluter/climate.py
Co-Authored-By: Paulus Schoutsen <paulus@home-assistant.io>
* Changed timeout from config, load platform discover to None
* Proposed change for discover info issue
Co-authored-by: Paulus Schoutsen <paulus@home-assistant.io>
* start of fan groups
* update fan classes
* update group entity domains
* add set speed
* update discovery for multiple entities for groups
* add fan group entity tests
* cleanup const
* cleanup entity_domain usage
* remove bad super call
* remove bad update line
* fix set speed on fan group
* change comparison
* pythonic list
* discovery guards
* Update homeassistant/components/zha/core/discovery.py
Co-Authored-By: Alexei Chetroi <lexoid@gmail.com>
Co-authored-by: Alexei Chetroi <lexoid@gmail.com>
* Abort rachio homekit config when one is already setup.
We can see rachio on the network to tell them to configure
it, but since the device will not give up the account it is
bound to and there can be multiple rachio controllers on a single
account, we avoid showing the device as discovered once
they already have one configured as they can always
add a new one via "+"
* doc string freshness
* doc string freshness
* Update tests/components/rachio/test_config_flow.py
Co-Authored-By: Franck Nijhof <git@frenck.dev>
Co-authored-by: Franck Nijhof <git@frenck.dev>