hass-core/homeassistant/components/greeneye_monitor.py
Jonathan Keljo 6395087a40 Upgrade greeneye_monitor to 1.0 ()
* Upgrade greeneye_monitor to 1.0

This is a breaking change; it causes the `serial_number` field in
configuration to be treated as the full 8-digit serial number rather
than the last 5 digits as was previously done, which results in the unique
identifiers for the sensors being different. (Fixing them up in
`config/.storage/core.entity_registry` before rebooting into the updated
version seems to prevent any weirdness.)

The last-5-digits behavior was a result of me misunderstanding the packet
format docs and not realizing that the true serial number was split across
two fields. In addition to being confusing (see
https://community.home-assistant.io/t/brultech-greeneye-issues/86852), it
was technically incorrect. The `greeneye_monitor` platform was just introduced
in 0.82, so it seems like the kind of thing that's best to fix now while
adoption is relatively low rather than later when somebody runs into it
as more than just a point of confusion.

* Switch to 8-character string

* Coerce to int

* Remove now-unnecessary cast
2019-01-11 20:54:22 -08:00

179 lines
5.4 KiB
Python

"""
Support for monitoring a GreenEye Monitor energy monitor.
For more details about this platform, please refer to the documentation at
https://home-assistant.io/components/greeneye_monitor/
"""
import logging
import voluptuous as vol
from homeassistant.const import (
CONF_NAME,
CONF_PORT,
CONF_TEMPERATURE_UNIT,
EVENT_HOMEASSISTANT_STOP)
import homeassistant.helpers.config_validation as cv
from homeassistant.helpers.discovery import async_load_platform
REQUIREMENTS = ['greeneye_monitor==1.0']
_LOGGER = logging.getLogger(__name__)
CONF_CHANNELS = 'channels'
CONF_COUNTED_QUANTITY = 'counted_quantity'
CONF_COUNTED_QUANTITY_PER_PULSE = 'counted_quantity_per_pulse'
CONF_MONITOR_SERIAL_NUMBER = 'monitor'
CONF_MONITORS = 'monitors'
CONF_NET_METERING = 'net_metering'
CONF_NUMBER = 'number'
CONF_PULSE_COUNTERS = 'pulse_counters'
CONF_SERIAL_NUMBER = 'serial_number'
CONF_SENSORS = 'sensors'
CONF_SENSOR_TYPE = 'sensor_type'
CONF_TEMPERATURE_SENSORS = 'temperature_sensors'
CONF_TIME_UNIT = 'time_unit'
DATA_GREENEYE_MONITOR = 'greeneye_monitor'
DOMAIN = 'greeneye_monitor'
SENSOR_TYPE_CURRENT = 'current_sensor'
SENSOR_TYPE_PULSE_COUNTER = 'pulse_counter'
SENSOR_TYPE_TEMPERATURE = 'temperature_sensor'
TEMPERATURE_UNIT_CELSIUS = 'C'
TIME_UNIT_SECOND = 's'
TIME_UNIT_MINUTE = 'min'
TIME_UNIT_HOUR = 'h'
TEMPERATURE_SENSOR_SCHEMA = vol.Schema({
vol.Required(CONF_NUMBER): vol.Range(1, 8),
vol.Required(CONF_NAME): cv.string,
})
TEMPERATURE_SENSORS_SCHEMA = vol.Schema({
vol.Required(CONF_TEMPERATURE_UNIT): cv.temperature_unit,
vol.Required(CONF_SENSORS): vol.All(cv.ensure_list,
[TEMPERATURE_SENSOR_SCHEMA]),
})
PULSE_COUNTER_SCHEMA = vol.Schema({
vol.Required(CONF_NUMBER): vol.Range(1, 4),
vol.Required(CONF_NAME): cv.string,
vol.Required(CONF_COUNTED_QUANTITY): cv.string,
vol.Optional(
CONF_COUNTED_QUANTITY_PER_PULSE, default=1.0): vol.Coerce(float),
vol.Optional(CONF_TIME_UNIT, default=TIME_UNIT_SECOND): vol.Any(
TIME_UNIT_SECOND,
TIME_UNIT_MINUTE,
TIME_UNIT_HOUR),
})
PULSE_COUNTERS_SCHEMA = vol.All(cv.ensure_list, [PULSE_COUNTER_SCHEMA])
CHANNEL_SCHEMA = vol.Schema({
vol.Required(CONF_NUMBER): vol.Range(1, 48),
vol.Required(CONF_NAME): cv.string,
vol.Optional(CONF_NET_METERING, default=False): cv.boolean,
})
CHANNELS_SCHEMA = vol.All(cv.ensure_list, [CHANNEL_SCHEMA])
MONITOR_SCHEMA = vol.Schema({
vol.Required(CONF_SERIAL_NUMBER):
vol.All(
cv.string,
vol.Length(
min=8,
max=8,
msg="GEM serial number must be specified as an 8-character "
"string (including leading zeroes)."),
vol.Coerce(int)),
vol.Optional(CONF_CHANNELS, default=[]): CHANNELS_SCHEMA,
vol.Optional(
CONF_TEMPERATURE_SENSORS,
default={
CONF_TEMPERATURE_UNIT: TEMPERATURE_UNIT_CELSIUS,
CONF_SENSORS: [],
}): TEMPERATURE_SENSORS_SCHEMA,
vol.Optional(CONF_PULSE_COUNTERS, default=[]): PULSE_COUNTERS_SCHEMA,
})
MONITORS_SCHEMA = vol.All(cv.ensure_list, [MONITOR_SCHEMA])
COMPONENT_SCHEMA = vol.Schema({
vol.Required(CONF_PORT): cv.port,
vol.Required(CONF_MONITORS): MONITORS_SCHEMA,
})
CONFIG_SCHEMA = vol.Schema({
DOMAIN: COMPONENT_SCHEMA,
}, extra=vol.ALLOW_EXTRA)
async def async_setup(hass, config):
"""Set up the GreenEye Monitor component."""
from greeneye import Monitors
monitors = Monitors()
hass.data[DATA_GREENEYE_MONITOR] = monitors
server_config = config[DOMAIN]
server = await monitors.start_server(server_config[CONF_PORT])
async def close_server(*args):
"""Close the monitoring server."""
await server.close()
hass.bus.async_listen_once(EVENT_HOMEASSISTANT_STOP, close_server)
all_sensors = []
for monitor_config in server_config[CONF_MONITORS]:
monitor_serial_number = {
CONF_MONITOR_SERIAL_NUMBER: monitor_config[CONF_SERIAL_NUMBER],
}
channel_configs = monitor_config[CONF_CHANNELS]
for channel_config in channel_configs:
all_sensors.append({
CONF_SENSOR_TYPE: SENSOR_TYPE_CURRENT,
**monitor_serial_number,
**channel_config,
})
sensor_configs = \
monitor_config[CONF_TEMPERATURE_SENSORS]
if sensor_configs:
temperature_unit = {
CONF_TEMPERATURE_UNIT: sensor_configs[CONF_TEMPERATURE_UNIT],
}
for sensor_config in sensor_configs[CONF_SENSORS]:
all_sensors.append({
CONF_SENSOR_TYPE: SENSOR_TYPE_TEMPERATURE,
**monitor_serial_number,
**temperature_unit,
**sensor_config,
})
counter_configs = monitor_config[CONF_PULSE_COUNTERS]
for counter_config in counter_configs:
all_sensors.append({
CONF_SENSOR_TYPE: SENSOR_TYPE_PULSE_COUNTER,
**monitor_serial_number,
**counter_config,
})
if not all_sensors:
_LOGGER.error("Configuration must specify at least one "
"channel, pulse counter or temperature sensor")
return False
hass.async_create_task(async_load_platform(
hass,
'sensor',
DOMAIN,
all_sensors,
config))
return True