"""Tests for 1-Wire devices connected on SysBus."""
|
|
from unittest.mock import patch
|
|
|
|
from pi1wire import InvalidCRCException, UnsupportResponseException
|
|
import pytest
|
|
|
|
from homeassistant.components.onewire.const import DEFAULT_SYSBUS_MOUNT_DIR, DOMAIN
|
|
from homeassistant.components.sensor import DOMAIN as SENSOR_DOMAIN
|
|
from homeassistant.const import DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS
|
|
from homeassistant.setup import async_setup_component
|
|
|
|
from tests.common import mock_device_registry, mock_registry
|
|
|
|
MOCK_CONFIG = {
|
|
SENSOR_DOMAIN: {
|
|
"platform": DOMAIN,
|
|
"mount_dir": DEFAULT_SYSBUS_MOUNT_DIR,
|
|
"names": {
|
|
"10-111111111111": "My DS18B20",
|
|
},
|
|
}
|
|
}
|
|
|
|
MOCK_DEVICE_SENSORS = {
|
|
"00-111111111111": {"sensors": []},
|
|
"10-111111111111": {
|
|
"device_info": {
|
|
"identifiers": {(DOMAIN, "10-111111111111")},
|
|
"manufacturer": "Maxim Integrated",
|
|
"model": "10",
|
|
"name": "10-111111111111",
|
|
},
|
|
"sensors": [
|
|
{
|
|
"entity_id": "sensor.my_ds18b20_temperature",
|
|
"unique_id": "/sys/bus/w1/devices/10-111111111111/w1_slave",
|
|
"injected_value": 25.123,
|
|
"result": "25.1",
|
|
"unit": TEMP_CELSIUS,
|
|
"class": DEVICE_CLASS_TEMPERATURE,
|
|
},
|
|
],
|
|
},
|
|
"12-111111111111": {"sensors": []},
|
|
"1D-111111111111": {"sensors": []},
|
|
"22-111111111111": {
|
|
"device_info": {
|
|
"identifiers": {(DOMAIN, "22-111111111111")},
|
|
"manufacturer": "Maxim Integrated",
|
|
"model": "22",
|
|
"name": "22-111111111111",
|
|
},
|
|
"sensors": [
|
|
{
|
|
"entity_id": "sensor.22_111111111111_temperature",
|
|
"unique_id": "/sys/bus/w1/devices/22-111111111111/w1_slave",
|
|
"injected_value": FileNotFoundError,
|
|
"result": "unknown",
|
|
"unit": TEMP_CELSIUS,
|
|
"class": DEVICE_CLASS_TEMPERATURE,
|
|
},
|
|
],
|
|
},
|
|
"26-111111111111": {"sensors": []},
|
|
"28-111111111111": {
|
|
"device_info": {
|
|
"identifiers": {(DOMAIN, "28-111111111111")},
|
|
"manufacturer": "Maxim Integrated",
|
|
"model": "28",
|
|
"name": "28-111111111111",
|
|
},
|
|
"sensors": [
|
|
{
|
|
"entity_id": "sensor.28_111111111111_temperature",
|
|
"unique_id": "/sys/bus/w1/devices/28-111111111111/w1_slave",
|
|
"injected_value": InvalidCRCException,
|
|
"result": "unknown",
|
|
"unit": TEMP_CELSIUS,
|
|
"class": DEVICE_CLASS_TEMPERATURE,
|
|
},
|
|
],
|
|
},
|
|
"29-111111111111": {"sensors": []},
|
|
"3B-111111111111": {
|
|
"device_info": {
|
|
"identifiers": {(DOMAIN, "3B-111111111111")},
|
|
"manufacturer": "Maxim Integrated",
|
|
"model": "3B",
|
|
"name": "3B-111111111111",
|
|
},
|
|
"sensors": [
|
|
{
|
|
"entity_id": "sensor.3b_111111111111_temperature",
|
|
"unique_id": "/sys/bus/w1/devices/3B-111111111111/w1_slave",
|
|
"injected_value": 29.993,
|
|
"result": "30.0",
|
|
"unit": TEMP_CELSIUS,
|
|
"class": DEVICE_CLASS_TEMPERATURE,
|
|
},
|
|
],
|
|
},
|
|
"42-111111111111": {
|
|
"device_info": {
|
|
"identifiers": {(DOMAIN, "42-111111111111")},
|
|
"manufacturer": "Maxim Integrated",
|
|
"model": "42",
|
|
"name": "42-111111111111",
|
|
},
|
|
"sensors": [
|
|
{
|
|
"entity_id": "sensor.42_111111111111_temperature",
|
|
"unique_id": "/sys/bus/w1/devices/42-111111111111/w1_slave",
|
|
"injected_value": UnsupportResponseException,
|
|
"result": "unknown",
|
|
"unit": TEMP_CELSIUS,
|
|
"class": DEVICE_CLASS_TEMPERATURE,
|
|
},
|
|
],
|
|
},
|
|
"EF-111111111111": {
|
|
"sensors": [],
|
|
},
|
|
"EF-111111111112": {
|
|
"sensors": [],
|
|
},
|
|
}
|
|
|
|
|
|
@pytest.mark.parametrize("device_id", MOCK_DEVICE_SENSORS.keys())
|
|
async def test_onewiredirect_setup_valid_device(hass, device_id):
|
|
"""Test that sysbus config entry works correctly."""
|
|
entity_registry = mock_registry(hass)
|
|
device_registry = mock_device_registry(hass)
|
|
|
|
mock_device_sensor = MOCK_DEVICE_SENSORS[device_id]
|
|
|
|
glob_result = [f"/{DEFAULT_SYSBUS_MOUNT_DIR}/{device_id}"]
|
|
read_side_effect = []
|
|
expected_sensors = mock_device_sensor["sensors"]
|
|
for expected_sensor in expected_sensors:
|
|
read_side_effect.append(expected_sensor["injected_value"])
|
|
|
|
# Ensure enough read side effect
|
|
read_side_effect.extend([FileNotFoundError("Missing injected value")] * 20)
|
|
|
|
with patch(
|
|
"homeassistant.components.onewire.onewirehub.os.path.isdir", return_value=True
|
|
), patch("pi1wire._finder.glob.glob", return_value=glob_result,), patch(
|
|
"pi1wire.OneWire.get_temperature",
|
|
side_effect=read_side_effect,
|
|
):
|
|
assert await async_setup_component(hass, SENSOR_DOMAIN, MOCK_CONFIG)
|
|
await hass.async_block_till_done()
|
|
|
|
assert len(entity_registry.entities) == len(expected_sensors)
|
|
|
|
if len(expected_sensors) > 0:
|
|
device_info = mock_device_sensor["device_info"]
|
|
assert len(device_registry.devices) == 1
|
|
registry_entry = device_registry.async_get_device({(DOMAIN, device_id)})
|
|
assert registry_entry is not None
|
|
assert registry_entry.identifiers == {(DOMAIN, device_id)}
|
|
assert registry_entry.manufacturer == device_info["manufacturer"]
|
|
assert registry_entry.name == device_info["name"]
|
|
assert registry_entry.model == device_info["model"]
|
|
|
|
for expected_sensor in expected_sensors:
|
|
entity_id = expected_sensor["entity_id"]
|
|
registry_entry = entity_registry.entities.get(entity_id)
|
|
assert registry_entry is not None
|
|
assert registry_entry.unique_id == expected_sensor["unique_id"]
|
|
assert registry_entry.unit_of_measurement == expected_sensor["unit"]
|
|
assert registry_entry.device_class == expected_sensor["class"]
|
|
state = hass.states.get(entity_id)
|
|
assert state.state == expected_sensor["result"]
|