665 lines
24 KiB
Python
665 lines
24 KiB
Python
"""Support for OpenTherm Gateway sensors."""
|
|
|
|
from dataclasses import dataclass
|
|
|
|
import pyotgw.vars as gw_vars
|
|
|
|
from homeassistant.components.sensor import (
|
|
ENTITY_ID_FORMAT,
|
|
SensorDeviceClass,
|
|
SensorEntity,
|
|
SensorEntityDescription,
|
|
SensorStateClass,
|
|
)
|
|
from homeassistant.config_entries import ConfigEntry
|
|
from homeassistant.const import (
|
|
CONF_ID,
|
|
PERCENTAGE,
|
|
UnitOfPower,
|
|
UnitOfPressure,
|
|
UnitOfTemperature,
|
|
UnitOfTime,
|
|
UnitOfVolumeFlowRate,
|
|
)
|
|
from homeassistant.core import HomeAssistant, callback
|
|
from homeassistant.helpers.entity import async_generate_entity_id
|
|
from homeassistant.helpers.entity_platform import AddEntitiesCallback
|
|
|
|
from . import OpenThermGatewayDevice
|
|
from .const import DATA_GATEWAYS, DATA_OPENTHERM_GW
|
|
from .entity import OpenThermEntity, OpenThermEntityDescription
|
|
|
|
SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION = 1
|
|
|
|
|
|
@dataclass(frozen=True, kw_only=True)
|
|
class OpenThermSensorEntityDescription(
|
|
SensorEntityDescription, OpenThermEntityDescription
|
|
):
|
|
"""Describes opentherm_gw sensor entity."""
|
|
|
|
|
|
SENSOR_INFO: tuple[tuple[list[str], OpenThermSensorEntityDescription], ...] = (
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_CONTROL_SETPOINT,
|
|
friendly_name_format="Control Setpoint {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_MASTER_MEMBERID,
|
|
friendly_name_format="Thermostat Member ID {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_SLAVE_MEMBERID,
|
|
friendly_name_format="Boiler Member ID {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_SLAVE_OEM_FAULT,
|
|
friendly_name_format="Boiler OEM Fault Code {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_COOLING_CONTROL,
|
|
friendly_name_format="Cooling Control Signal {}",
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=PERCENTAGE,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_CONTROL_SETPOINT_2,
|
|
friendly_name_format="Control Setpoint 2 {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_ROOM_SETPOINT_OVRD,
|
|
friendly_name_format="Room Setpoint Override {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_SLAVE_MAX_RELATIVE_MOD,
|
|
friendly_name_format="Boiler Maximum Relative Modulation {}",
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=PERCENTAGE,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_SLAVE_MAX_CAPACITY,
|
|
friendly_name_format="Boiler Maximum Capacity {}",
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
device_class=SensorDeviceClass.POWER,
|
|
native_unit_of_measurement=UnitOfPower.KILO_WATT,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_SLAVE_MIN_MOD_LEVEL,
|
|
friendly_name_format="Boiler Minimum Modulation Level {}",
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=PERCENTAGE,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_ROOM_SETPOINT,
|
|
friendly_name_format="Room Setpoint {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_REL_MOD_LEVEL,
|
|
friendly_name_format="Relative Modulation Level {}",
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=PERCENTAGE,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_CH_WATER_PRESS,
|
|
friendly_name_format="Central Heating Water Pressure {}",
|
|
device_class=SensorDeviceClass.PRESSURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfPressure.BAR,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_DHW_FLOW_RATE,
|
|
friendly_name_format="Hot Water Flow Rate {}",
|
|
device_class=SensorDeviceClass.VOLUME_FLOW_RATE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfVolumeFlowRate.LITERS_PER_MINUTE,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_ROOM_SETPOINT_2,
|
|
friendly_name_format="Room Setpoint 2 {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_ROOM_TEMP,
|
|
friendly_name_format="Room Temperature {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_CH_WATER_TEMP,
|
|
friendly_name_format="Central Heating Water Temperature {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_DHW_TEMP,
|
|
friendly_name_format="Hot Water Temperature {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_OUTSIDE_TEMP,
|
|
friendly_name_format="Outside Temperature {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_RETURN_WATER_TEMP,
|
|
friendly_name_format="Return Water Temperature {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_SOLAR_STORAGE_TEMP,
|
|
friendly_name_format="Solar Storage Temperature {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_SOLAR_COLL_TEMP,
|
|
friendly_name_format="Solar Collector Temperature {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_CH_WATER_TEMP_2,
|
|
friendly_name_format="Central Heating 2 Water Temperature {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_DHW_TEMP_2,
|
|
friendly_name_format="Hot Water 2 Temperature {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_EXHAUST_TEMP,
|
|
friendly_name_format="Exhaust Temperature {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_SLAVE_DHW_MAX_SETP,
|
|
friendly_name_format="Hot Water Maximum Setpoint {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_SLAVE_DHW_MIN_SETP,
|
|
friendly_name_format="Hot Water Minimum Setpoint {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_SLAVE_CH_MAX_SETP,
|
|
friendly_name_format="Boiler Maximum Central Heating Setpoint {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_SLAVE_CH_MIN_SETP,
|
|
friendly_name_format="Boiler Minimum Central Heating Setpoint {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_DHW_SETPOINT,
|
|
friendly_name_format="Hot Water Setpoint {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_MAX_CH_SETPOINT,
|
|
friendly_name_format="Maximum Central Heating Setpoint {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_OEM_DIAG,
|
|
friendly_name_format="OEM Diagnostic Code {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_TOTAL_BURNER_STARTS,
|
|
friendly_name_format="Total Burner Starts {}",
|
|
state_class=SensorStateClass.TOTAL,
|
|
native_unit_of_measurement="starts",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_CH_PUMP_STARTS,
|
|
friendly_name_format="Central Heating Pump Starts {}",
|
|
state_class=SensorStateClass.TOTAL,
|
|
native_unit_of_measurement="starts",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_DHW_PUMP_STARTS,
|
|
friendly_name_format="Hot Water Pump Starts {}",
|
|
state_class=SensorStateClass.TOTAL,
|
|
native_unit_of_measurement="starts",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_DHW_BURNER_STARTS,
|
|
friendly_name_format="Hot Water Burner Starts {}",
|
|
state_class=SensorStateClass.TOTAL,
|
|
native_unit_of_measurement="starts",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_TOTAL_BURNER_HOURS,
|
|
friendly_name_format="Total Burner Hours {}",
|
|
device_class=SensorDeviceClass.DURATION,
|
|
state_class=SensorStateClass.TOTAL,
|
|
native_unit_of_measurement=UnitOfTime.HOURS,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_CH_PUMP_HOURS,
|
|
friendly_name_format="Central Heating Pump Hours {}",
|
|
device_class=SensorDeviceClass.DURATION,
|
|
state_class=SensorStateClass.TOTAL,
|
|
native_unit_of_measurement=UnitOfTime.HOURS,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_DHW_PUMP_HOURS,
|
|
friendly_name_format="Hot Water Pump Hours {}",
|
|
device_class=SensorDeviceClass.DURATION,
|
|
state_class=SensorStateClass.TOTAL,
|
|
native_unit_of_measurement=UnitOfTime.HOURS,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_DHW_BURNER_HOURS,
|
|
friendly_name_format="Hot Water Burner Hours {}",
|
|
device_class=SensorDeviceClass.DURATION,
|
|
state_class=SensorStateClass.TOTAL,
|
|
native_unit_of_measurement=UnitOfTime.HOURS,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_MASTER_OT_VERSION,
|
|
friendly_name_format="Thermostat OpenTherm Version {}",
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_SLAVE_OT_VERSION,
|
|
friendly_name_format="Boiler OpenTherm Version {}",
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_MASTER_PRODUCT_TYPE,
|
|
friendly_name_format="Thermostat Product Type {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_MASTER_PRODUCT_VERSION,
|
|
friendly_name_format="Thermostat Product Version {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_SLAVE_PRODUCT_TYPE,
|
|
friendly_name_format="Boiler Product Type {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.BOILER, gw_vars.THERMOSTAT],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.DATA_SLAVE_PRODUCT_VERSION,
|
|
friendly_name_format="Boiler Product Version {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.OTGW],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.OTGW_MODE,
|
|
friendly_name_format="Gateway/Monitor Mode {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.OTGW],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.OTGW_DHW_OVRD,
|
|
friendly_name_format="Gateway Hot Water Override Mode {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.OTGW],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.OTGW_ABOUT,
|
|
friendly_name_format="Gateway Firmware Version {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.OTGW],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.OTGW_BUILD,
|
|
friendly_name_format="Gateway Firmware Build {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.OTGW],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.OTGW_CLOCKMHZ,
|
|
friendly_name_format="Gateway Clock Speed {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.OTGW],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.OTGW_LED_A,
|
|
friendly_name_format="Gateway LED A Mode {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.OTGW],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.OTGW_LED_B,
|
|
friendly_name_format="Gateway LED B Mode {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.OTGW],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.OTGW_LED_C,
|
|
friendly_name_format="Gateway LED C Mode {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.OTGW],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.OTGW_LED_D,
|
|
friendly_name_format="Gateway LED D Mode {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.OTGW],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.OTGW_LED_E,
|
|
friendly_name_format="Gateway LED E Mode {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.OTGW],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.OTGW_LED_F,
|
|
friendly_name_format="Gateway LED F Mode {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.OTGW],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.OTGW_GPIO_A,
|
|
friendly_name_format="Gateway GPIO A Mode {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.OTGW],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.OTGW_GPIO_B,
|
|
friendly_name_format="Gateway GPIO B Mode {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.OTGW],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.OTGW_SB_TEMP,
|
|
friendly_name_format="Gateway Setback Temperature {}",
|
|
device_class=SensorDeviceClass.TEMPERATURE,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
|
|
suggested_display_precision=SENSOR_FLOAT_SUGGESTED_DISPLAY_PRECISION,
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.OTGW],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.OTGW_SETP_OVRD_MODE,
|
|
friendly_name_format="Gateway Room Setpoint Override Mode {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.OTGW],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.OTGW_SMART_PWR,
|
|
friendly_name_format="Gateway Smart Power Mode {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.OTGW],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.OTGW_THRM_DETECT,
|
|
friendly_name_format="Gateway Thermostat Detection {}",
|
|
),
|
|
),
|
|
(
|
|
[gw_vars.OTGW],
|
|
OpenThermSensorEntityDescription(
|
|
key=gw_vars.OTGW_VREF,
|
|
friendly_name_format="Gateway Reference Voltage Setting {}",
|
|
),
|
|
),
|
|
)
|
|
|
|
|
|
async def async_setup_entry(
|
|
hass: HomeAssistant,
|
|
config_entry: ConfigEntry,
|
|
async_add_entities: AddEntitiesCallback,
|
|
) -> None:
|
|
"""Set up the OpenTherm Gateway sensors."""
|
|
gw_dev = hass.data[DATA_OPENTHERM_GW][DATA_GATEWAYS][config_entry.data[CONF_ID]]
|
|
|
|
async_add_entities(
|
|
OpenThermSensor(
|
|
gw_dev,
|
|
source,
|
|
description,
|
|
)
|
|
for sources, description in SENSOR_INFO
|
|
for source in sources
|
|
)
|
|
|
|
|
|
class OpenThermSensor(OpenThermEntity, SensorEntity):
|
|
"""Representation of an OpenTherm Gateway sensor."""
|
|
|
|
entity_description: OpenThermSensorEntityDescription
|
|
|
|
def __init__(
|
|
self,
|
|
gw_dev: OpenThermGatewayDevice,
|
|
source: str,
|
|
description: OpenThermSensorEntityDescription,
|
|
) -> None:
|
|
"""Initialize the OpenTherm Gateway sensor."""
|
|
self.entity_id = async_generate_entity_id(
|
|
ENTITY_ID_FORMAT,
|
|
f"{description.key}_{source}_{gw_dev.gw_id}",
|
|
hass=gw_dev.hass,
|
|
)
|
|
super().__init__(gw_dev, source, description)
|
|
|
|
@callback
|
|
def receive_report(self, status: dict[str, dict]) -> None:
|
|
"""Handle status updates from the component."""
|
|
self._attr_available = self._gateway.connected
|
|
value = status[self._source].get(self.entity_description.key)
|
|
self._attr_native_value = value
|
|
self.async_write_ha_state()
|