""" Support for ZWave HVAC devices. For more details about this platform, please refer to the documentation at https://home-assistant.io/components/hvac.zwave/ """ # Because we do not compile openzwave on CI # pylint: disable=import-error import logging from homeassistant.components.hvac import DOMAIN from homeassistant.components.hvac import HvacDevice from homeassistant.components.zwave import ( ATTR_NODE_ID, ATTR_VALUE_ID, ZWaveDeviceEntity) from homeassistant.components import zwave from homeassistant.const import (TEMP_FAHRENHEIT, TEMP_CELSIUS) _LOGGER = logging.getLogger(__name__) CONF_NAME = 'name' DEFAULT_NAME = 'ZWave Hvac' REMOTEC = 0x5254 REMOTEC_ZXT_120 = 0x8377 REMOTEC_ZXT_120_THERMOSTAT = (REMOTEC, REMOTEC_ZXT_120, 0) COMMAND_CLASS_SENSOR_MULTILEVEL = 0x31 COMMAND_CLASS_THERMOSTAT_MODE = 0x40 COMMAND_CLASS_THERMOSTAT_SETPOINT = 0x43 COMMAND_CLASS_THERMOSTAT_FAN_MODE = 0x44 COMMAND_CLASS_CONFIGURATION = 0x70 WORKAROUND_ZXT_120 = 'zxt_120' DEVICE_MAPPINGS = { REMOTEC_ZXT_120_THERMOSTAT: WORKAROUND_ZXT_120 } ZXT_120_SET_TEMP = { 'Heat': 1, 'Cool': 2, 'Dry Air': 8, 'Auto Changeover': 10 } def setup_platform(hass, config, add_devices, discovery_info=None): """Setup the ZWave Hvac devices.""" if discovery_info is None or zwave.NETWORK is None: _LOGGER.debug("No discovery_info=%s or no NETWORK=%s", discovery_info, zwave.NETWORK) return node = zwave.NETWORK.nodes[discovery_info[ATTR_NODE_ID]] value = node.values[discovery_info[ATTR_VALUE_ID]] value.set_change_verified(False) add_devices([ZWaveHvac(value)]) _LOGGER.debug("discovery_info=%s and zwave.NETWORK=%s", discovery_info, zwave.NETWORK) # pylint: disable=too-many-arguments, abstract-method class ZWaveHvac(ZWaveDeviceEntity, HvacDevice): """Represents a HeatControl hvac.""" # pylint: disable=too-many-public-methods, too-many-instance-attributes def __init__(self, value): """Initialize the zwave hvac.""" from openzwave.network import ZWaveNetwork from pydispatch import dispatcher ZWaveDeviceEntity.__init__(self, value, DOMAIN) self._node = value.node self._target_temperature = None self._current_temperature = None self._current_operation = None self._operation_list = None self._current_operation_state = None self._current_fan_mode = None self._fan_list = None self._current_swing_mode = None self._swing_list = None self._unit = None self._zxt_120 = None self.update_properties() # register listener dispatcher.connect( self.value_changed, ZWaveNetwork.SIGNAL_VALUE_CHANGED) # Make sure that we have values for the key before converting to int if (value.node.manufacturer_id.strip() and value.node.product_id.strip()): specific_sensor_key = (int(value.node.manufacturer_id, 16), int(value.node.product_id, 16), value.index) if specific_sensor_key in DEVICE_MAPPINGS: if DEVICE_MAPPINGS[specific_sensor_key] == WORKAROUND_ZXT_120: _LOGGER.debug("Remotec ZXT-120 Zwave Thermostat as HVAC") self._zxt_120 = 1 def value_changed(self, value): """Called when a value has changed on the network.""" if self._value.value_id == value.value_id or \ self._value.node == value.node: self.update_properties() self.update_ha_state() _LOGGER.debug("Value changed on network %s", value) def update_properties(self): """Callback on data change for the registered node/value pair.""" # Set point for value in self._node.get_values( class_id=COMMAND_CLASS_THERMOSTAT_SETPOINT).values(): if int(value.data) != 0: self._target_temperature = int(value.data) # Operation Mode for value in self._node.get_values( class_id=COMMAND_CLASS_THERMOSTAT_MODE).values(): self._current_operation = value.data self._operation_list = list(value.data_items) _LOGGER.debug("self._operation_list=%s", self._operation_list) # Current Temp for value in self._node.get_values( class_id=COMMAND_CLASS_SENSOR_MULTILEVEL).values(): self._current_temperature = int(value.data) self._unit = value.units # Fan Mode for value in self._node.get_values( class_id=COMMAND_CLASS_THERMOSTAT_FAN_MODE).values(): self._current_operation_state = value.data self._fan_list = list(value.data_items) _LOGGER.debug("self._fan_list=%s", self._fan_list) _LOGGER.debug("self._current_operation_state=%s", self._current_operation_state) # Swing mode if self._zxt_120 == 1: for value in self._node.get_values( class_id=COMMAND_CLASS_CONFIGURATION).values(): if value.command_class == 112 and value.index == 33: self._current_swing_mode = value.data self._swing_list = list(value.data_items) _LOGGER.debug("self._swing_list=%s", self._swing_list) @property def should_poll(self): """No polling on ZWave.""" return False @property def current_fan_mode(self): """Return the fan speed set.""" return self._current_operation_state @property def fan_list(self): """List of available fan modes.""" return self._fan_list @property def current_swing_mode(self): """Return the swing mode set.""" return self._current_swing_mode @property def swing_list(self): """List of available swing modes.""" return self._swing_list @property def unit_of_measurement(self): """Return the unit of measurement.""" unit = self._unit if unit == 'C': return TEMP_CELSIUS elif unit == 'F': return TEMP_FAHRENHEIT else: _LOGGER.exception("unit_of_measurement=%s is not valid", unit) @property def current_temperature(self): """Return the current temperature.""" return self._current_temperature @property def current_operation(self): """Return the current operation mode.""" return self._current_operation @property def operation_list(self): """List of available operation modes.""" return self._operation_list @property def target_temperature(self): """Return the temperature we try to reach.""" return self._target_temperature def set_temperature(self, temperature): """Set new target temperature.""" for value in self._node.get_values( class_id=COMMAND_CLASS_THERMOSTAT_SETPOINT).values(): if value.command_class != 67: continue if self._zxt_120: # ZXT-120 does not support get setpoint self._target_temperature = temperature if ZXT_120_SET_TEMP.get(self._current_operation) \ != value.index: continue # ZXT-120 responds only to whole int value.data = int(round(temperature, 0)) else: value.data = int(temperature) break def set_fan_mode(self, fan): """Set new target fan mode.""" for value in self._node.get_values( class_id=COMMAND_CLASS_THERMOSTAT_FAN_MODE).values(): if value.command_class == 68 and value.index == 0: value.data = bytes(fan, 'utf-8') break def set_operation_mode(self, operation_mode): """Set new target operation mode.""" for value in self._node.get_values( class_id=COMMAND_CLASS_THERMOSTAT_MODE).values(): if value.command_class == 64 and value.index == 0: value.data = bytes(operation_mode, 'utf-8') break def set_swing_mode(self, swing_mode): """Set new target swing mode.""" if self._zxt_120 == 1: for value in self._node.get_values( class_id=COMMAND_CLASS_CONFIGURATION).values(): if value.command_class == 112 and value.index == 33: value.data = bytes(swing_mode, 'utf-8') break