Commit graph

23 commits

Author SHA1 Message Date
Hans Oischinger
35fa73eee9
vicare: Don't create unsupportedd button entites (#79425)
Button entities should only be offered when the datapoint exists on
the API.
2022-10-01 22:17:25 +03:00
J. Nick Koston
cd03c49fc2
Wait for config entry platform forwards (#73806) 2022-07-09 17:27:42 +02:00
epenet
6245d28907
Remove YAML configuration from vicare (#72408) 2022-05-24 20:28:09 +02:00
Hans Oischinger
8d6880ab85
Support systems w/o circuits (#64779) 2022-01-24 11:18:54 +01:00
Hans Oischinger
2969a7ab4f
Address late review of vicare config flow (#63343)
* Review comments from #56691

* Adapt to review suggestions

* Update homeassistant/components/vicare/strings.json

Co-authored-by: Martin Hjelmare <marhje52@gmail.com>

Co-authored-by: Martin Hjelmare <marhje52@gmail.com>
2022-01-05 22:49:42 +01:00
epenet
e7b262f9e5
Add init type hints [v-z] (#63195)
Co-authored-by: epenet <epenet@users.noreply.github.com>
2022-01-02 16:27:12 +01:00
Marc Mueller
de78c4f0f8
Import Callable from collections.abc (#60354) 2021-11-25 22:23:48 +01:00
Hans Oischinger
38b976e6d6
Add vicare config flow (#56691)
* Configuration via UI

Config flow / YAML deprecation
- Support discovery via MAC address
- Support import of YAML config
- Switch to ConfigEntry, get rid of platform setup

* Fix review comments

* More tests for vicare yaml import
2021-11-22 15:06:42 +01:00
Hans Oischinger
66ae116023
Update PyVicare to 2.13.0 (#57700)
* Update PyVicare to 2.x

With PyViCare 2.8.1 a breaking change was introduced which required changes on sensor and binary_sensor platforms:
- Circuit, Burner and Compressor have been separated out from the "main" device
- Multiple circuits and burners allow "duplicate sensors". We add the circuit or burner number as suffix now

At the same time the sensors are now created only when available:
During entity creation we can check if the value is provided for the user's device.

Sensors are not created by heating type anymore but instead the new API structure is reflected, providing device, burner or circuit sensors.

For details of breaking changes from PyViCare 1.x to 2.x please see https://github.com/somm15/PyViCare#breaking-changes-in-version-2x

* Integrate review comments

* variables cleanup

* Update unique ids

The unique ids shall not depend on the name but on the entity
description key (which should not change) and the id of the circuit,
burner or device.
2021-10-25 13:43:43 +02:00
Marc Mueller
d51487f82a
Import Callable from collections.abc (3) (#56777) 2021-09-29 16:19:06 +02:00
Marc Mueller
2b51896d7a
Use EntityDescription - vicare (#55932)
* Use EntityDescription - vicare binary_sensor

* Use EntityDescription - vicare sensor

* Fix typing

* Remove default values

* Fix pylint
2021-09-14 22:06:06 +02:00
Hans Oischinger
84dc6af760
Update to PyVicare 1.0 (#53281) 2021-07-22 21:56:38 +02:00
Nicolas Braem
96857b7466
Add vicare fuelcell (#47167) 2021-03-31 11:29:24 +02:00
Marc Mueller
2956eb0902
Update pylint to 2.7.3 (#48488)
* Update pylint to 2.7.3

* Add class-const-naming-style

* Remove unused-import message

* Additional cleanup
2021-03-29 18:02:56 -10:00
Quentame
198ecb0945
Uniformize platform setup (#47101)
* A platform is not a component

* Fix dynalite

* SUPPORTED_PLATFORMS --> PLATFORMS

* In tests

* In tests 2

* Fix SmartThings

* Fix ZHA test

* Fix Z-Wave

* Revert Z-Wave

* Use PLATFORMS const in ambient_station

* Fix ihc comment
2021-03-02 21:43:59 +01:00
Marc Mueller
16dcbf1467
Update pylint (#47205) 2021-02-28 22:09:01 -10:00
Franck Nijhof
53545c984b
Log lines do not end with a full stop (#37527) 2020-07-05 23:04:19 +02:00
Martin
0bbb56dd05
Add sensor platform for vicare integration (heatpump) (#34385)
* Add sensor platform for vicare (heatpump)

* Formatting and fixes

* Formatting and fixes 2

* Fixes and formatting 3

* Fixes and formatting 4

* Add binary_sensor and more sensors

This moves some more climate attributes to sensors and adds
binary_sensors

* Move ActiveError back to climate component

The data returned by ActiveError is more complex.
It takes further investigation on how to interpret it a s a binary sensor.
Therefore it is moved back as an attribute of the climate component

* Update PyViCare library

* PR changes

* PR changes 2

Co-authored-by: Hans Oischinger <hans.oischinger@gmail.com>
2020-06-13 21:53:42 +02:00
Hans Oischinger
4a2236fe85
:vicare: Improve scan_interval (#33294)
This upgrades to PyVicare 0.1.10 which allows to combine multiple
requests into a single HTTP GET. This in turn allows us to increase
the scan_interval to 60 seconds by default.
Additionally scan_interval has been introduced as a config parameter.
2020-03-28 12:12:27 +01:00
Ville Skyttä
5e2ba2eb77
Enable some more bandit checks (#30857)
* Enable B108 (hardcoded tmp dir), address findings

* Enable B602 (subprocess popen with shell), address findings

* Enable B604 (start process with shell), address findings

* Enable B306 (mktemp), B307 (eval), and B325 (tempnam), no issues to address
2020-01-20 18:44:55 +02:00
Bas Nijholt
f281069c8c Sort imports according to PEP8 for vicare (#29754) 2019-12-09 13:13:33 +01:00
Martin
06c26f3ffc Add heating_type for ViCare integration (#27296)
* Add heating_type for ViCare

* Add additional gas heating properties

* Update requirements_all

* Add hvac action

* Remove measurements

* Remove unused property
2019-11-04 20:12:43 +01:00
Hans Oischinger
a72d9da9f4 Add Viessmann ViCare Climate platform (#26151)
* Add Viessmann ViCare Climate platform

* Add water_heater and fix review comments
Update to latest PyVicare (0.1.0)

* Move PyVicare API creation to component

* More review fixes

* Return false if api creation fails

* Fix logging format

* Update PyVicare 0.1.1 to fix json issues

* Formatting fixes
2019-09-06 22:09:03 +02:00