Commit graph

13 commits

Author SHA1 Message Date
Alexey ALERT Rubashёff
0fe939cd7c
Update overkiz Atlantic Water Heater operation mode switching (#124619)
* conventional operation state usage

* MartinHjelmare indentation request

* Manual Mode binary sensor

* Removed usage of unconventional operation states

* Removed usage of unconventional operation state

* STATE_OFF operation mode support
2024-08-26 21:31:07 +02:00
Alexey ALERT Rubashёff
195643d916
Improve AtlanticDomesticHotWaterProductionMBLComponent support in Overkiz (#114178)
* add overkiz AtlanticDHW support

Adds support of Overkiz water heater entity selection based on device controllable_name
Adds support of Atlantic water heater based on Atlantic Steatite Cube WI-FI VM 150 S4CS 2400W
Adds more Overkiz water heater binary_sensors, numbers, and sensors

* Changed class annotation

* min_temp and max_temp as properties

* reverted binary_sensors, number, sensor to make separate PRs

* Update homeassistant/components/overkiz/water_heater_entities/atlantic_dhw.py

Co-authored-by: Mick Vleeshouwer <mick@imick.nl>

* Update homeassistant/components/overkiz/water_heater_entities/atlantic_dhw.py

Co-authored-by: Mick Vleeshouwer <mick@imick.nl>

* Update homeassistant/components/overkiz/water_heater_entities/atlantic_dhw.py

Co-authored-by: Mick Vleeshouwer <mick@imick.nl>

* Update homeassistant/components/overkiz/water_heater.py

Co-authored-by: Mick Vleeshouwer <mick@imick.nl>

* Update homeassistant/components/overkiz/water_heater_entities/atlantic_dhw.py

Co-authored-by: Mick Vleeshouwer <mick@imick.nl>

* Update homeassistant/components/overkiz/water_heater_entities/atlantic_dhw.py

Co-authored-by: Mick Vleeshouwer <mick@imick.nl>

* review fixes, typos, and pylint

* review fix

* review fix

* ruff

* temperature properties changed to constructor attributes

* logger removed

* constants usage consistency

* redundant mapping removed

* Update homeassistant/components/overkiz/water_heater_entities/atlantic_dhw.py

Co-authored-by: Mick Vleeshouwer <mick@imick.nl>

* boost mode method annotation typo

* removed away mode for atlantic dwh

* absence and boost mode attributes now support 'prog' state

* heating status bugfix

* electrical consumption sensor

* warm water remaining volume sensor

* away mode reintroduced

* mypy check

* boost plus state support

* Update homeassistant/components/overkiz/sensor.py

Co-authored-by: Mick Vleeshouwer <mick@imick.nl>

* sensors reverted to separate them into their own PR

* check away and boost modes on before switching them off

* atlantic_dhw renamed to atlantic_domestic_hot_water_production

* annotation changed

* AtlanticDomesticHotWaterProductionMBLComponent file renamed, annotation change reverted

---------

Co-authored-by: Mick Vleeshouwer <mick@imick.nl>
2024-06-27 22:05:58 +02:00
Alexey ALERT Rubashёff
3381469076
Add overkiz heating status, absence mode, and boost mode binary sensors for Atlantic Water Heater (#114184)
* Adds heating status, absense mode, and boost mode binary sensors for Atlantic water heater

* Renamed absence mode and boost mode binary sensors

* Update homeassistant/components/overkiz/binary_sensor.py

Co-authored-by: TheJulianJES <TheJulianJES@users.noreply.github.com>

* Update homeassistant/components/overkiz/binary_sensor.py

Co-authored-by: TheJulianJES <TheJulianJES@users.noreply.github.com>

* Update homeassistant/components/overkiz/binary_sensor.py

Co-authored-by: TheJulianJES <TheJulianJES@users.noreply.github.com>

---------

Co-authored-by: TheJulianJES <TheJulianJES@users.noreply.github.com>
2024-03-29 14:07:22 +01:00
Joost Lekkerkerker
e6a692f354
Improve lists in integrations [N-O] (#113231) 2024-03-13 21:51:38 +01:00
Joost Lekkerkerker
dec98d424f
Remove entity description mixin in Overkiz (#112914) 2024-03-10 18:06:17 +01:00
Marc Mueller
988c71ecc5
Add empty line after module docstring [n-q] (#112702) 2024-03-08 15:04:07 +01:00
Erik Montnemery
0c2485bc03
Freeze integration entity descriptions (#105984)
Co-authored-by: J. Nick Koston <nick@koston.org>
2023-12-18 16:28:13 -10:00
Mick Vleeshouwer
8f6884ac10
Add new Binary Sensor description to Overkiz integration (#64322) 2022-01-17 10:46:20 -10:00
Mick Vleeshouwer
05c177e3ed
Address late feedback to Overkiz (move to constants) (#64324) 2022-01-17 10:25:24 -10:00
Mick Vleeshouwer
1cf2f0b944
Simplify coordinator and import OverkizStateType (#63969) 2022-01-13 02:23:20 +01:00
Mick Vleeshouwer
b4187540c0
Improve typing for Overkiz integration and address late feedback (#63483)
* Bump pyoverkiz to 1.0.2

* Remove cast for str enum.

* Address feedback on coordinator

* Change datatype to Callable

* Address feedback

* Move scenarios to seperate list

* Cast Device to avoid issues with DataUpdateCoordinator default

* Remove unnecessary casts and improve type notation

* Check if state.value exists

* Fix last mypy error (thanks @epenet)

* Remove extra string cast

* Improve sensor typing

* Update pyoverkiz and remove typing

* Small code improvement

* Fix assert to reflect real world

* Properly type Callable to not return Any

* Remove unnecessary cast

* Add OverkizStateType

* Bugfix

* Address feedback - multiline lambda

* Pylint fix

* Remove added binary sensor
2022-01-08 10:53:15 +01:00
Mick Vleeshouwer
4eb077b6b4
Enable strict typing for Overkiz integration (#63108) 2021-12-31 07:35:15 -10:00
Mick Vleeshouwer
41c497ee6e
Add binary sensor entity to Overkiz integration (#62913) 2021-12-27 23:10:39 -10:00