Simplify calls to pymodbus (#50717)
* simplify pymodbus_call. Do not call with a function object and a check attribute, call instead with CALL_TYPE*. Avoid if <type> call x else call y. Call async_pymodbus_call directly, instead of unpacking/packing. * Declare call type in __init__. * Modbus.py back to 100% test coverage.
This commit is contained in:
parent
7b18860dcd
commit
ff856a9bba
5 changed files with 92 additions and 34 deletions
|
@ -151,12 +151,9 @@ class ModbusBinarySensor(BinarySensorEntity):
|
|||
"""Update the state of the sensor."""
|
||||
# remark "now" is a dummy parameter to avoid problems with
|
||||
# async_track_time_interval
|
||||
if self._input_type == CALL_TYPE_COIL:
|
||||
result = await self._hub.async_read_coils(self._slave, self._address, 1)
|
||||
else:
|
||||
result = await self._hub.async_read_discrete_inputs(
|
||||
self._slave, self._address, 1
|
||||
)
|
||||
result = await self._hub.async_pymodbus_call(
|
||||
self._slave, self._address, 1, self._input_type
|
||||
)
|
||||
if result is None:
|
||||
self._available = False
|
||||
self.async_write_ha_state()
|
||||
|
|
|
@ -75,6 +75,10 @@ CALL_TYPE_COIL = "coil"
|
|||
CALL_TYPE_DISCRETE = "discrete_input"
|
||||
CALL_TYPE_REGISTER_HOLDING = "holding"
|
||||
CALL_TYPE_REGISTER_INPUT = "input"
|
||||
CALL_TYPE_WRITE_COIL = "write_coil"
|
||||
CALL_TYPE_WRITE_COILS = "write_coils"
|
||||
CALL_TYPE_WRITE_REGISTER = "write_register"
|
||||
CALL_TYPE_WRITE_REGISTERS = "write_registers"
|
||||
|
||||
# service calls
|
||||
SERVICE_WRITE_COIL = "write_coil"
|
||||
|
|
|
@ -27,6 +27,14 @@ from .const import (
|
|||
ATTR_STATE,
|
||||
ATTR_UNIT,
|
||||
ATTR_VALUE,
|
||||
CALL_TYPE_COIL,
|
||||
CALL_TYPE_DISCRETE,
|
||||
CALL_TYPE_REGISTER_HOLDING,
|
||||
CALL_TYPE_REGISTER_INPUT,
|
||||
CALL_TYPE_WRITE_COIL,
|
||||
CALL_TYPE_WRITE_COILS,
|
||||
CALL_TYPE_WRITE_REGISTER,
|
||||
CALL_TYPE_WRITE_REGISTERS,
|
||||
CONF_BAUDRATE,
|
||||
CONF_BYTESIZE,
|
||||
CONF_CLOSE_COMM_ON_ERROR,
|
||||
|
@ -39,6 +47,9 @@ from .const import (
|
|||
SERVICE_WRITE_REGISTER,
|
||||
)
|
||||
|
||||
ENTRY_FUNC = "func"
|
||||
ENTRY_ATTR = "attr"
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
|
||||
|
@ -145,6 +156,41 @@ class ModbusHub:
|
|||
# network configuration
|
||||
self._config_host = client_config[CONF_HOST]
|
||||
|
||||
self._call_type = {
|
||||
CALL_TYPE_COIL: {
|
||||
ENTRY_ATTR: "bits",
|
||||
ENTRY_FUNC: None,
|
||||
},
|
||||
CALL_TYPE_DISCRETE: {
|
||||
ENTRY_ATTR: "bits",
|
||||
ENTRY_FUNC: None,
|
||||
},
|
||||
CALL_TYPE_REGISTER_HOLDING: {
|
||||
ENTRY_ATTR: "registers",
|
||||
ENTRY_FUNC: None,
|
||||
},
|
||||
CALL_TYPE_REGISTER_INPUT: {
|
||||
ENTRY_ATTR: "registers",
|
||||
ENTRY_FUNC: None,
|
||||
},
|
||||
CALL_TYPE_WRITE_COIL: {
|
||||
ENTRY_ATTR: "value",
|
||||
ENTRY_FUNC: None,
|
||||
},
|
||||
CALL_TYPE_WRITE_COILS: {
|
||||
ENTRY_ATTR: "count",
|
||||
ENTRY_FUNC: None,
|
||||
},
|
||||
CALL_TYPE_WRITE_REGISTER: {
|
||||
ENTRY_ATTR: "value",
|
||||
ENTRY_FUNC: None,
|
||||
},
|
||||
CALL_TYPE_WRITE_REGISTERS: {
|
||||
ENTRY_ATTR: "count",
|
||||
ENTRY_FUNC: None,
|
||||
},
|
||||
}
|
||||
|
||||
@property
|
||||
def name(self):
|
||||
"""Return the name of this hub."""
|
||||
|
@ -202,6 +248,25 @@ class ModbusHub:
|
|||
async with self._lock:
|
||||
await self.hass.async_add_executor_job(self._pymodbus_connect)
|
||||
|
||||
self._call_type[CALL_TYPE_COIL][ENTRY_FUNC] = self._client.read_coils
|
||||
self._call_type[CALL_TYPE_DISCRETE][
|
||||
ENTRY_FUNC
|
||||
] = self._client.read_discrete_inputs
|
||||
self._call_type[CALL_TYPE_REGISTER_HOLDING][
|
||||
ENTRY_FUNC
|
||||
] = self._client.read_holding_registers
|
||||
self._call_type[CALL_TYPE_REGISTER_INPUT][
|
||||
ENTRY_FUNC
|
||||
] = self._client.read_input_registers
|
||||
self._call_type[CALL_TYPE_WRITE_COIL][ENTRY_FUNC] = self._client.write_coil
|
||||
self._call_type[CALL_TYPE_WRITE_COILS][ENTRY_FUNC] = self._client.write_coils
|
||||
self._call_type[CALL_TYPE_WRITE_REGISTER][
|
||||
ENTRY_FUNC
|
||||
] = self._client.write_register
|
||||
self._call_type[CALL_TYPE_WRITE_REGISTERS][
|
||||
ENTRY_FUNC
|
||||
] = self._client.write_registers
|
||||
|
||||
# Start counting down to allow modbus requests.
|
||||
if self._config_delay:
|
||||
self._async_cancel_listener = async_call_later(
|
||||
|
@ -239,73 +304,69 @@ class ModbusHub:
|
|||
except ModbusException as exception_error:
|
||||
self._log_error(exception_error, error_state=False)
|
||||
|
||||
def _pymodbus_call(self, unit, address, value, check_attr, func):
|
||||
def _pymodbus_call(self, unit, address, value, use_call):
|
||||
"""Call sync. pymodbus."""
|
||||
kwargs = {"unit": unit} if unit else {}
|
||||
try:
|
||||
result = func(address, value, **kwargs)
|
||||
result = self._call_type[use_call][ENTRY_FUNC](address, value, **kwargs)
|
||||
except ModbusException as exception_error:
|
||||
self._log_error(exception_error)
|
||||
result = exception_error
|
||||
if not hasattr(result, check_attr):
|
||||
if not hasattr(result, self._call_type[use_call][ENTRY_ATTR]):
|
||||
self._log_error(result)
|
||||
return None
|
||||
self._in_error = False
|
||||
return result
|
||||
|
||||
async def async_pymodbus_call(self, unit, address, value, check_attr, func):
|
||||
async def async_pymodbus_call(self, unit, address, value, use_call):
|
||||
"""Convert async to sync pymodbus call."""
|
||||
if self._config_delay:
|
||||
return None
|
||||
async with self._lock:
|
||||
return await self.hass.async_add_executor_job(
|
||||
self._pymodbus_call, unit, address, value, check_attr, func
|
||||
self._pymodbus_call, unit, address, value, use_call
|
||||
)
|
||||
|
||||
async def async_read_coils(self, unit, address, count):
|
||||
"""Read coils."""
|
||||
return await self.async_pymodbus_call(
|
||||
unit, address, count, "bits", self._client.read_coils
|
||||
)
|
||||
return await self.async_pymodbus_call(unit, address, count, CALL_TYPE_COIL)
|
||||
|
||||
async def async_read_discrete_inputs(self, unit, address, count):
|
||||
"""Read discrete inputs."""
|
||||
return await self.async_pymodbus_call(
|
||||
unit, address, count, "bits", self._client.read_discrete_inputs
|
||||
)
|
||||
return await self.async_pymodbus_call(unit, address, count, CALL_TYPE_DISCRETE)
|
||||
|
||||
async def async_read_input_registers(self, unit, address, count):
|
||||
"""Read input registers."""
|
||||
return await self.async_pymodbus_call(
|
||||
unit, address, count, "registers", self._client.read_input_registers
|
||||
unit, address, count, CALL_TYPE_REGISTER_INPUT
|
||||
)
|
||||
|
||||
async def async_read_holding_registers(self, unit, address, count):
|
||||
"""Read holding registers."""
|
||||
return await self.async_pymodbus_call(
|
||||
unit, address, count, "registers", self._client.read_holding_registers
|
||||
unit, address, count, CALL_TYPE_REGISTER_HOLDING
|
||||
)
|
||||
|
||||
async def async_write_coil(self, unit, address, value) -> bool:
|
||||
"""Write coil."""
|
||||
return await self.async_pymodbus_call(
|
||||
unit, address, value, "value", self._client.write_coil
|
||||
unit, address, value, CALL_TYPE_WRITE_COIL
|
||||
)
|
||||
|
||||
async def async_write_coils(self, unit, address, values) -> bool:
|
||||
"""Write coil."""
|
||||
return await self.async_pymodbus_call(
|
||||
unit, address, values, "count", self._client.write_coils
|
||||
unit, address, values, CALL_TYPE_WRITE_COILS
|
||||
)
|
||||
|
||||
async def async_write_register(self, unit, address, value) -> bool:
|
||||
"""Write register."""
|
||||
return await self.async_pymodbus_call(
|
||||
unit, address, value, "value", self._client.write_register
|
||||
unit, address, value, CALL_TYPE_WRITE_REGISTER
|
||||
)
|
||||
|
||||
async def async_write_registers(self, unit, address, values) -> bool:
|
||||
"""Write registers."""
|
||||
return await self.async_pymodbus_call(
|
||||
unit, address, values, "count", self._client.write_registers
|
||||
unit, address, values, CALL_TYPE_WRITE_REGISTERS
|
||||
)
|
||||
|
|
|
@ -283,14 +283,9 @@ class ModbusRegisterSensor(RestoreEntity, SensorEntity):
|
|||
"""Update the state of the sensor."""
|
||||
# remark "now" is a dummy parameter to avoid problems with
|
||||
# async_track_time_interval
|
||||
if self._register_type == CALL_TYPE_REGISTER_INPUT:
|
||||
result = await self._hub.async_read_input_registers(
|
||||
self._slave, self._register, self._count
|
||||
)
|
||||
else:
|
||||
result = await self._hub.async_read_holding_registers(
|
||||
self._slave, self._register, self._count
|
||||
)
|
||||
result = await self._hub.async_pymodbus_call(
|
||||
self._slave, self._register, self._count, self._register_type
|
||||
)
|
||||
if result is None:
|
||||
self._available = False
|
||||
self.async_write_ha_state()
|
||||
|
|
|
@ -3,6 +3,7 @@ import pytest
|
|||
|
||||
from homeassistant.components.modbus.const import (
|
||||
CALL_TYPE_COIL,
|
||||
CALL_TYPE_DISCRETE,
|
||||
CALL_TYPE_REGISTER_HOLDING,
|
||||
CALL_TYPE_REGISTER_INPUT,
|
||||
CONF_COILS,
|
||||
|
@ -232,11 +233,11 @@ async def test_service_switch_update(hass, mock_pymodbus):
|
|||
CONF_NAME: "test",
|
||||
CONF_ADDRESS: 1234,
|
||||
CONF_WRITE_TYPE: CALL_TYPE_COIL,
|
||||
CONF_VERIFY: {},
|
||||
CONF_VERIFY: {CONF_INPUT_TYPE: CALL_TYPE_DISCRETE},
|
||||
}
|
||||
]
|
||||
}
|
||||
mock_pymodbus.read_coils.return_value = ReadResult([0x01])
|
||||
mock_pymodbus.read_discrete_inputs.return_value = ReadResult([0x01])
|
||||
await prepare_service_update(
|
||||
hass,
|
||||
config,
|
||||
|
@ -245,7 +246,7 @@ async def test_service_switch_update(hass, mock_pymodbus):
|
|||
"homeassistant", "update_entity", {"entity_id": entity_id}, blocking=True
|
||||
)
|
||||
assert hass.states.get(entity_id).state == STATE_ON
|
||||
mock_pymodbus.read_coils.return_value = ReadResult([0x00])
|
||||
mock_pymodbus.read_discrete_inputs.return_value = ReadResult([0x00])
|
||||
await hass.services.async_call(
|
||||
"homeassistant", "update_entity", {"entity_id": entity_id}, blocking=True
|
||||
)
|
||||
|
|
Loading…
Add table