Fix Comelit alarm state (#106466)
This commit is contained in:
parent
a78ecb3895
commit
f7d482c85b
1 changed files with 1 additions and 3 deletions
|
@ -127,15 +127,13 @@ class ComelitAlarmEntity(CoordinatorEntity[ComelitVedoSystem], AlarmControlPanel
|
|||
return STATE_ALARM_ARMED_NIGHT
|
||||
return STATE_ALARM_ARMED_HOME
|
||||
|
||||
{
|
||||
return {
|
||||
AlarmAreaState.DISARMED: STATE_ALARM_DISARMED,
|
||||
AlarmAreaState.ENTRY_DELAY: STATE_ALARM_DISARMING,
|
||||
AlarmAreaState.EXIT_DELAY: STATE_ALARM_ARMING,
|
||||
AlarmAreaState.TRIGGERED: STATE_ALARM_TRIGGERED,
|
||||
}.get(self._area.human_status)
|
||||
|
||||
return None
|
||||
|
||||
async def async_alarm_disarm(self, code: str | None = None) -> None:
|
||||
"""Send disarm command."""
|
||||
if code != str(self._api.device_pin):
|
||||
|
|