Add OpenTherm Gateway sensor platform.

* Remove library imports from platforms (use hass.data instead)
* Update .coveragerc
* Update docstrings to use new component documentation url
This commit is contained in:
mvn23 2018-10-06 14:41:19 +02:00
parent 442bc0f75b
commit b3505ed561
4 changed files with 338 additions and 57 deletions

View file

@ -242,6 +242,9 @@ omit =
homeassistant/components/opencv.py
homeassistant/components/*/opencv.py
homeassistant/components/opentherm_gw.py
homeassistant/components/*/opentherm_gw.py
homeassistant/components/openuv/__init__.py
homeassistant/components/*/openuv.py
@ -429,7 +432,6 @@ omit =
homeassistant/components/climate/honeywell.py
homeassistant/components/climate/knx.py
homeassistant/components/climate/oem.py
homeassistant/components/climate/opentherm_gw.py
homeassistant/components/climate/proliphix.py
homeassistant/components/climate/radiotherm.py
homeassistant/components/climate/sensibo.py

View file

@ -1,23 +1,20 @@
"""
Support for OpenTherm Gateway devices.
Support for OpenTherm Gateway climate devices.
For more details about this component, please refer to the documentation at
http://home-assistant.io/components/climate.opentherm_gw/
For more details about this platform, please refer to the documentation at
http://home-assistant.io/components/opentherm_gw/
"""
import logging
import voluptuous as vol
from homeassistant.components.climate import (ClimateDevice, PLATFORM_SCHEMA,
STATE_IDLE, STATE_HEAT,
STATE_COOL,
from homeassistant.components.climate import (ClimateDevice, STATE_IDLE,
STATE_HEAT, STATE_COOL,
SUPPORT_TARGET_TEMPERATURE)
from homeassistant.components.opentherm_gw import SIGNAL_OPENTHERM_GW_UPDATE
from homeassistant.const import (ATTR_TEMPERATURE, CONF_DEVICE, CONF_NAME,
PRECISION_HALVES, PRECISION_TENTHS,
TEMP_CELSIUS, PRECISION_WHOLE)
from homeassistant.components.opentherm_gw import (
DATA_DEVICE, DATA_GW_VARS, DATA_OPENTHERM_GW, SIGNAL_OPENTHERM_GW_UPDATE)
from homeassistant.const import (ATTR_TEMPERATURE, CONF_NAME, PRECISION_HALVES,
PRECISION_TENTHS, TEMP_CELSIUS,
PRECISION_WHOLE)
from homeassistant.helpers.dispatcher import async_dispatcher_connect
import homeassistant.helpers.config_validation as cv
DEPENDENCIES = ['opentherm_gw']
@ -31,20 +28,20 @@ _LOGGER = logging.getLogger(__name__)
async def async_setup_platform(hass, config, async_add_entities,
discovery_info=None):
"""Set up the opentherm_gw device."""
gateway = OpenThermGateway(discovery_info)
gateway = OpenThermGateway(hass, discovery_info)
async_add_entities([gateway])
class OpenThermGateway(ClimateDevice):
"""Representation of a climate device."""
def __init__(self, config):
def __init__(self, hass, config):
"""Initialize the device."""
import pyotgw
self.pyotgw = pyotgw
self.friendly_name = config.get(CONF_NAME)
self.floor_temp = config.get(CONF_FLOOR_TEMP)
self.temp_precision = config.get(CONF_PRECISION)
self._gateway = hass.data[DATA_OPENTHERM_GW][DATA_DEVICE]
self._gw_vars = hass.data[DATA_OPENTHERM_GW][DATA_GW_VARS]
self._current_operation = STATE_IDLE
self._current_temperature = 0.0
self._target_temperature = 0.0
@ -55,39 +52,39 @@ class OpenThermGateway(ClimateDevice):
async def async_added_to_hass(self):
"""Connect to the OpenTherm Gateway device."""
_LOGGER.debug("Added device {}".format(self.friendly_name))
_LOGGER.debug("Added device %s", self.friendly_name)
async_dispatcher_connect(self.hass, SIGNAL_OPENTHERM_GW_UPDATE,
self.receive_report)
async def receive_report(self, status):
"""Receive and handle a new report from the Gateway."""
_LOGGER.debug("Received report: %s", status)
ch_active = status.get(self.pyotgw.DATA_SLAVE_CH_ACTIVE)
flame_on = status.get(self.pyotgw.DATA_SLAVE_FLAME_ON)
cooling_active = status.get(self.pyotgw.DATA_SLAVE_COOLING_ACTIVE)
ch_active = status.get(self._gw_vars.DATA_SLAVE_CH_ACTIVE)
flame_on = status.get(self._gw_vars.DATA_SLAVE_FLAME_ON)
cooling_active = status.get(self._gw_vars.DATA_SLAVE_COOLING_ACTIVE)
if ch_active and flame_on:
self._current_operation = STATE_HEAT
elif cooling_active:
self._current_operation = STATE_COOL
else:
self._current_operation = STATE_IDLE
self._current_temperature = status.get(self.pyotgw.DATA_ROOM_TEMP)
self._current_temperature = status.get(self._gw_vars.DATA_ROOM_TEMP)
temp = status.get(self.pyotgw.DATA_ROOM_SETPOINT_OVRD)
temp = status.get(self._gw_vars.DATA_ROOM_SETPOINT_OVRD)
if temp is None:
temp = status.get(self.pyotgw.DATA_ROOM_SETPOINT)
temp = status.get(self._gw_vars.DATA_ROOM_SETPOINT)
self._target_temperature = temp
# GPIO mode 5: 0 == Away
# GPIO mode 6: 1 == Away
gpio_a_state = status.get(self.pyotgw.OTGW_GPIO_A)
gpio_a_state = status.get(self._gw_vars.OTGW_GPIO_A)
if gpio_a_state == 5:
self._away_mode_a = 0
elif gpio_a_state == 6:
self._away_mode_a = 1
else:
self._away_mode_a = None
gpio_b_state = status.get(self.pyotgw.OTGW_GPIO_B)
gpio_b_state = status.get(self._gw_vars.OTGW_GPIO_B)
if gpio_b_state == 5:
self._away_mode_b = 0
elif gpio_b_state == 6:
@ -95,11 +92,11 @@ class OpenThermGateway(ClimateDevice):
else:
self._away_mode_b = None
if self._away_mode_a is not None:
self._away_state_a = (status.get(self.pyotgw.OTGW_GPIO_A_STATE) ==
self._away_mode_a)
self._away_state_a = (status.get(
self._gw_vars.OTGW_GPIO_A_STATE) == self._away_mode_a)
if self._away_mode_b is not None:
self._away_state_b = (status.get(self.pyotgw.OTGW_GPIO_B_STATE) ==
self._away_mode_b)
self._away_state_b = (status.get(
self._gw_vars.OTGW_GPIO_B_STATE) == self._away_mode_b)
self.async_schedule_update_ha_state()
@property
@ -161,7 +158,7 @@ class OpenThermGateway(ClimateDevice):
"""Set new target temperature."""
if ATTR_TEMPERATURE in kwargs:
temp = float(kwargs[ATTR_TEMPERATURE])
self._target_temperature = await self.gateway.set_target_temp(
self._target_temperature = await self._gateway.set_target_temp(
temp)
self.async_schedule_update_ha_state()

View file

@ -1,21 +1,32 @@
import asyncio
"""
Support for OpenTherm Gateway devices.
For more details about this component, please refer to the documentation at
http://home-assistant.io/components/opentherm_gw/
"""
import logging
import voluptuous as vol
from homeassistant.helpers.discovery import (async_load_platform,
async_listen_platform)
from homeassistant.helpers.discovery import async_load_platform
from homeassistant.helpers.dispatcher import async_dispatcher_send
from homeassistant.const import (CONF_BINARY_SENSORS, CONF_DEVICE,
CONF_MONITORED_VARIABLES, CONF_NAME,
CONF_SENSORS, PRECISION_HALVES,
PRECISION_TENTHS, PRECISION_WHOLE)
from homeassistant.const import (CONF_DEVICE, CONF_MONITORED_VARIABLES,
CONF_NAME, PRECISION_HALVES, PRECISION_TENTHS,
PRECISION_WHOLE)
import homeassistant.helpers.config_validation as cv
DOMAIN = 'opentherm_gw'
COMP_SENSOR = 'sensor'
COMP_BINARY_SENSOR = 'binary_sensor'
CONF_CLIMATE = 'climate'
CONF_FLOOR_TEMP = 'floor_temperature'
CONF_PRECISION = 'precision'
DATA_DEVICE = 'device'
DATA_GW_VARS = 'gw_vars'
DATA_OPENTHERM_GW = 'opentherm_gw'
SIGNAL_OPENTHERM_GW_UPDATE = 'opentherm_gw_update'
CLIMATE_SCHEMA = vol.Schema({
@ -25,42 +36,41 @@ CLIMATE_SCHEMA = vol.Schema({
vol.Optional(CONF_FLOOR_TEMP, default=False): cv.boolean,
})
SENSOR_SCHEMA = vol.Schema({
vol.Optional(CONF_MONITORED_VARIABLES, default=[]): cv.ensure_list,
})
CONFIG_SCHEMA = vol.Schema({
DOMAIN: vol.Schema({
vol.Required(CONF_DEVICE): cv.string,
vol.Optional(CONF_CLIMATE, default=CLIMATE_SCHEMA({})):
CLIMATE_SCHEMA,
vol.Optional(CONF_SENSORS, default=SENSOR_SCHEMA({})): SENSOR_SCHEMA,
vol.Optional(CONF_BINARY_SENSORS, default=SENSOR_SCHEMA({})):
SENSOR_SCHEMA,
vol.Optional(CONF_MONITORED_VARIABLES, default=[]): cv.ensure_list,
}),
}, extra = vol.ALLOW_EXTRA)
}, extra=vol.ALLOW_EXTRA)
REQUIREMENTS = ['pyotgw==0.1b0']
_LOGGER = logging.getLogger(__name__)
async def async_setup(hass, config):
"""Set up the OpenTherm Gateway component."""
conf = config.get(DOMAIN)
if conf is None:
return True
import pyotgw
hass.data[DATA_OPENTHERM_GW] = {
DATA_DEVICE: pyotgw.pyotgw(),
DATA_GW_VARS: pyotgw.vars,
}
hass.async_add_job(connect_and_subscribe, hass, conf)
hass.async_create_task(async_load_platform(
hass, 'climate', DOMAIN, conf.get(CONF_CLIMATE)))
#hass.async_create_task(async_load_platform(
# hass, 'sensor', DOMAIN, conf.get(CONF_MONITORED_VARIABLES)))
#hass.async_create_task(async_load_platform(
# hass, 'binary_sensor', DOMAIN, conf.get(CONF_MONITORED_VARIABLES)))
hass.async_add_job(setup_monitored_vars, hass,
conf.get(CONF_MONITORED_VARIABLES))
return True
async def connect_and_subscribe(hass, conf):
"""Connect to serial device and subscribe report handler."""
import pyotgw
gateway = pyotgw.pyotgw()
gateway = hass.data[DATA_OPENTHERM_GW][DATA_DEVICE]
await gateway.connect(hass.loop, conf[CONF_DEVICE])
async def handle_report(status):
@ -68,7 +78,96 @@ async def connect_and_subscribe(hass, conf):
async_dispatcher_send(hass, SIGNAL_OPENTHERM_GW_UPDATE, status)
gateway.subscribe(handle_report)
# class OpenThermSensor(Entity):
# """Basic functionality for opentherm_gw sensor."""
#
async def setup_monitored_vars(hass, monitored_vars):
"""Setup requested sensors and binary_sensors."""
gw_vars = hass.data[DATA_OPENTHERM_GW][DATA_GW_VARS]
sensor_type_map = {
gw_vars.DATA_MASTER_CH_ENABLED: COMP_BINARY_SENSOR,
gw_vars.DATA_MASTER_DHW_ENABLED: COMP_BINARY_SENSOR,
gw_vars.DATA_MASTER_COOLING_ENABLED: COMP_BINARY_SENSOR,
gw_vars.DATA_MASTER_OTC_ENABLED: COMP_BINARY_SENSOR,
gw_vars.DATA_MASTER_CH2_ENABLED: COMP_BINARY_SENSOR,
gw_vars.DATA_SLAVE_FAULT_IND: COMP_BINARY_SENSOR,
gw_vars.DATA_SLAVE_CH_ACTIVE: COMP_BINARY_SENSOR,
gw_vars.DATA_SLAVE_DHW_ACTIVE: COMP_BINARY_SENSOR,
gw_vars.DATA_SLAVE_FLAME_ON: COMP_BINARY_SENSOR,
gw_vars.DATA_SLAVE_COOLING_ACTIVE: COMP_BINARY_SENSOR,
gw_vars.DATA_SLAVE_CH2_ACTIVE: COMP_BINARY_SENSOR,
gw_vars.DATA_SLAVE_DIAG_IND: COMP_BINARY_SENSOR,
gw_vars.DATA_CONTROL_SETPOINT: COMP_SENSOR,
gw_vars.DATA_MASTER_MEMBERID: COMP_SENSOR,
gw_vars.DATA_SLAVE_DHW_PRESENT: COMP_BINARY_SENSOR,
gw_vars.DATA_SLAVE_CONTROL_TYPE: COMP_BINARY_SENSOR,
gw_vars.DATA_SLAVE_COOLING_SUPPORTED: COMP_BINARY_SENSOR,
gw_vars.DATA_SLAVE_DHW_CONFIG: COMP_BINARY_SENSOR,
gw_vars.DATA_SLAVE_MASTER_LOW_OFF_PUMP: COMP_BINARY_SENSOR,
gw_vars.DATA_SLAVE_CH2_PRESENT: COMP_BINARY_SENSOR,
gw_vars.DATA_SLAVE_MEMBERID: COMP_SENSOR,
gw_vars.DATA_SLAVE_SERVICE_REQ: COMP_BINARY_SENSOR,
gw_vars.DATA_SLAVE_REMOTE_RESET: COMP_BINARY_SENSOR,
gw_vars.DATA_SLAVE_LOW_WATER_PRESS: COMP_BINARY_SENSOR,
gw_vars.DATA_SLAVE_GAS_FAULT: COMP_BINARY_SENSOR,
gw_vars.DATA_SLAVE_AIR_PRESS_FAULT: COMP_BINARY_SENSOR,
gw_vars.DATA_SLAVE_WATER_OVERTEMP: COMP_BINARY_SENSOR,
gw_vars.DATA_SLAVE_OEM_FAULT: COMP_SENSOR,
gw_vars.DATA_REMOTE_TRANSFER_DHW: COMP_BINARY_SENSOR,
gw_vars.DATA_REMOTE_TRANSFER_MAX_CH: COMP_BINARY_SENSOR,
gw_vars.DATA_REMOTE_RW_DHW: COMP_BINARY_SENSOR,
gw_vars.DATA_REMOTE_RW_MAX_CH: COMP_BINARY_SENSOR,
gw_vars.DATA_COOLING_CONTROL: COMP_SENSOR,
gw_vars.DATA_CONTROL_SETPOINT_2: COMP_SENSOR,
gw_vars.DATA_ROOM_SETPOINT_OVRD: COMP_SENSOR,
gw_vars.DATA_SLAVE_MAX_RELATIVE_MOD: COMP_SENSOR,
gw_vars.DATA_SLAVE_MAX_CAPACITY: COMP_SENSOR,
gw_vars.DATA_SLAVE_MIN_MOD_LEVEL: COMP_SENSOR,
gw_vars.DATA_ROOM_SETPOINT: COMP_SENSOR,
gw_vars.DATA_REL_MOD_LEVEL: COMP_SENSOR,
gw_vars.DATA_CH_WATER_PRESS: COMP_SENSOR,
gw_vars.DATA_DHW_FLOW_RATE: COMP_SENSOR,
gw_vars.DATA_ROOM_SETPOINT_2: COMP_SENSOR,
gw_vars.DATA_ROOM_TEMP: COMP_SENSOR,
gw_vars.DATA_CH_WATER_TEMP: COMP_SENSOR,
gw_vars.DATA_DHW_TEMP: COMP_SENSOR,
gw_vars.DATA_OUTSIDE_TEMP: COMP_SENSOR,
gw_vars.DATA_RETURN_WATER_TEMP: COMP_SENSOR,
gw_vars.DATA_SOLAR_STORAGE_TEMP: COMP_SENSOR,
gw_vars.DATA_SOLAR_COLL_TEMP: COMP_SENSOR,
gw_vars.DATA_CH_WATER_TEMP_2: COMP_SENSOR,
gw_vars.DATA_DHW_TEMP_2: COMP_SENSOR,
gw_vars.DATA_EXHAUST_TEMP: COMP_SENSOR,
gw_vars.DATA_SLAVE_DHW_MAX_SETP: COMP_SENSOR,
gw_vars.DATA_SLAVE_DHW_MIN_SETP: COMP_SENSOR,
gw_vars.DATA_SLAVE_CH_MAX_SETP: COMP_SENSOR,
gw_vars.DATA_SLAVE_CH_MIN_SETP: COMP_SENSOR,
gw_vars.DATA_DHW_SETPOINT: COMP_SENSOR,
gw_vars.DATA_MAX_CH_SETPOINT: COMP_SENSOR,
gw_vars.DATA_ROVRD_MAN_PRIO: COMP_BINARY_SENSOR,
gw_vars.DATA_ROVRD_AUTO_PRIO: COMP_BINARY_SENSOR,
gw_vars.DATA_OEM_DIAG: COMP_SENSOR,
gw_vars.DATA_CH_BURNER_STARTS: COMP_SENSOR,
gw_vars.DATA_CH_PUMP_STARTS: COMP_SENSOR,
gw_vars.DATA_DHW_PUMP_STARTS: COMP_SENSOR,
gw_vars.DATA_DHW_BURNER_STARTS: COMP_SENSOR,
gw_vars.DATA_CH_BURNER_HOURS: COMP_SENSOR,
gw_vars.DATA_CH_PUMP_HOURS: COMP_SENSOR,
gw_vars.DATA_DHW_PUMP_HOURS: COMP_SENSOR,
gw_vars.DATA_DHW_BURNER_HOURS: COMP_SENSOR,
gw_vars.DATA_MASTER_OT_VERSION: COMP_SENSOR,
gw_vars.DATA_SLAVE_OT_VERSION: COMP_SENSOR,
gw_vars.DATA_MASTER_PRODUCT_TYPE: COMP_SENSOR,
gw_vars.DATA_MASTER_PRODUCT_VERSION: COMP_SENSOR,
gw_vars.DATA_SLAVE_PRODUCT_TYPE: COMP_SENSOR,
gw_vars.DATA_SLAVE_PRODUCT_VERSION: COMP_SENSOR,
}
sensors = {COMP_SENSOR: [], COMP_BINARY_SENSOR: []}
for var in monitored_vars:
if var not in sensor_type_map:
_LOGGER.error("Monitored variable not supported: %s", var)
continue
sensors[sensor_type_map[var]].append(var)
if sensors[COMP_SENSOR]:
hass.async_create_task(async_load_platform(
hass, COMP_SENSOR, DOMAIN, sensors[COMP_SENSOR]))
if sensors[COMP_BINARY_SENSOR]:
hass.async_create_task(async_load_platform(
hass, COMP_BINARY_SENSOR, DOMAIN, sensors[COMP_BINARY_SENSOR]))

View file

@ -0,0 +1,183 @@
"""
Support for OpenTherm Gateway sensors.
For more details about this platform, please refer to the documentation at
http://home-assistant.io/components/opentherm_gw/
"""
import logging
from homeassistant.components.opentherm_gw import (
DATA_GW_VARS, DATA_OPENTHERM_GW, SIGNAL_OPENTHERM_GW_UPDATE)
from homeassistant.components.sensor import ENTITY_ID_FORMAT
from homeassistant.const import DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS
from homeassistant.helpers.dispatcher import async_dispatcher_connect
from homeassistant.helpers.entity import Entity, async_generate_entity_id
UNIT_BAR = 'bar'
UNIT_HOUR = 'h'
UNIT_KW = 'kW'
UNIT_L_MIN = 'L/min'
UNIT_PERCENT = '%'
DEPENDENCIES = ['opentherm_gw']
_LOGGER = logging.getLogger(__name__)
async def async_setup_platform(hass, config, async_add_entities,
discovery_info=None):
"""Set up the OpenTherm Gateway sensors."""
gw_vars = hass.data[DATA_OPENTHERM_GW][DATA_GW_VARS]
sensor_info = {
# [device_class, unit, friendly_name]
gw_vars.DATA_CONTROL_SETPOINT: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Control Setpoint"],
gw_vars.DATA_MASTER_MEMBERID: [None, None, "Thermostat Member ID"],
gw_vars.DATA_SLAVE_MEMBERID: [None, None, "Boiler Member ID"],
gw_vars.DATA_SLAVE_OEM_FAULT: [None, None, "Boiler OEM Fault Code"],
gw_vars.DATA_COOLING_CONTROL: [
None, UNIT_PERCENT, "Cooling Control Signal"],
gw_vars.DATA_CONTROL_SETPOINT_2: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Control Setpoint 2"],
gw_vars.DATA_ROOM_SETPOINT_OVRD: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Room Setpoint Override"],
gw_vars.DATA_SLAVE_MAX_RELATIVE_MOD: [
None, UNIT_PERCENT, "Boiler Maximum Relative Modulation"],
gw_vars.DATA_SLAVE_MAX_CAPACITY: [
None, UNIT_KW, "Boiler Maximum Capacity"],
gw_vars.DATA_SLAVE_MIN_MOD_LEVEL: [
None, UNIT_PERCENT, "Boiler Minimum Modulation Level"],
gw_vars.DATA_ROOM_SETPOINT: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Room Setpoint"],
gw_vars.DATA_REL_MOD_LEVEL: [
None, UNIT_PERCENT, "Relative Modulation Level"],
gw_vars.DATA_CH_WATER_PRESS: [
None, UNIT_BAR, "Central Heating Water Pressure"],
gw_vars.DATA_DHW_FLOW_RATE: [None, UNIT_L_MIN, "Hot Water Flow Rate"],
gw_vars.DATA_ROOM_SETPOINT_2: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Room Setpoint 2"],
gw_vars.DATA_ROOM_TEMP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Room Temperature"],
gw_vars.DATA_CH_WATER_TEMP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Central Heating Water Temperature"],
gw_vars.DATA_DHW_TEMP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Hot Water Temperature"],
gw_vars.DATA_OUTSIDE_TEMP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Outside Temperature"],
gw_vars.DATA_RETURN_WATER_TEMP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Return Water Temperature"],
gw_vars.DATA_SOLAR_STORAGE_TEMP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Solar Storage Temperature"],
gw_vars.DATA_SOLAR_COLL_TEMP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Solar Collector Temperature"],
gw_vars.DATA_CH_WATER_TEMP_2: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Central Heating 2 Water Temperature"],
gw_vars.DATA_DHW_TEMP_2: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Hot Water 2 Temperature"],
gw_vars.DATA_EXHAUST_TEMP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Exhaust Temperature"],
gw_vars.DATA_SLAVE_DHW_MAX_SETP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Hot Water Maximum Setpoint"],
gw_vars.DATA_SLAVE_DHW_MIN_SETP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Hot Water Minimum Setpoint"],
gw_vars.DATA_SLAVE_CH_MAX_SETP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Boiler Maximum Central Heating Setpoint"],
gw_vars.DATA_SLAVE_CH_MIN_SETP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Boiler Minimum Central Heating Setpoint"],
gw_vars.DATA_DHW_SETPOINT: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Hot Water Setpoint"],
gw_vars.DATA_MAX_CH_SETPOINT: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Maximum Central Heating Setpoint"],
gw_vars.DATA_OEM_DIAG: [None, None, "OEM Diagnostic Code"],
gw_vars.DATA_CH_BURNER_STARTS: [
None, None, "Central Heating Burner Starts"],
gw_vars.DATA_CH_PUMP_STARTS: [None, None, "Central Heating Pump Starts"],
gw_vars.DATA_DHW_PUMP_STARTS: [None, None, "Hot Water Pump Starts"],
gw_vars.DATA_DHW_BURNER_STARTS: [None, None, "Hot Water Burner Starts"],
gw_vars.DATA_CH_BURNER_HOURS: [
None, UNIT_HOUR, "Central Heating Burner Hours"],
gw_vars.DATA_CH_PUMP_HOURS: [
None, UNIT_HOUR, "Central Heating Pump Hours"],
gw_vars.DATA_DHW_PUMP_HOURS: [None, UNIT_HOUR, "Hot Water Pump Hours"],
gw_vars.DATA_DHW_BURNER_HOURS: [
None, UNIT_HOUR, "Hot Water Burner Hours"],
gw_vars.DATA_MASTER_OT_VERSION: [
None, None, "Thermostat OpenTherm Version"],
gw_vars.DATA_SLAVE_OT_VERSION: [None, None, "Boiler OpenTherm Version"],
gw_vars.DATA_MASTER_PRODUCT_TYPE: [None, None, "Thermostat Product Type"],
gw_vars.DATA_MASTER_PRODUCT_VERSION: [
None, None, "Thermostat Product Version"],
gw_vars.DATA_SLAVE_PRODUCT_TYPE: [None, None, "Boiler Product Type"],
gw_vars.DATA_SLAVE_PRODUCT_VERSION: [
None, None, "Boiler Product Version"],
}
sensors = []
for var in discovery_info:
device_class = sensor_info[var][0]
unit = sensor_info[var][1]
friendly_name = sensor_info[var][2]
sensors.append(
OpenThermSensor(hass, var, device_class, unit, friendly_name))
async_add_entities(sensors)
class OpenThermSensor(Entity):
"""Representation of an OpenTherm Gateway sensor."""
def __init__(self, hass, var, device_class, unit, friendly_name):
"""Initialize the sensor."""
self.entity_id = async_generate_entity_id(ENTITY_ID_FORMAT, var,
hass=hass)
self._var = var
self._value = None
self._device_class = device_class
self._unit = unit
self._friendly_name = friendly_name
async def async_added_to_hass(self):
"""Subscribe to updates from the component."""
_LOGGER.debug("Added OpenTherm Gateway sensor %s", self._friendly_name)
async_dispatcher_connect(self.hass, SIGNAL_OPENTHERM_GW_UPDATE,
self.receive_report)
async def receive_report(self, status):
"""Handle status updates from the component."""
value = status.get(self._var)
if isinstance(value, float):
value = '{:2.1f}'.format(value)
self._value = value
self.async_schedule_update_ha_state()
@property
def name(self):
"""Return the friendly name of the sensor."""
return self._friendly_name
@property
def device_class(self):
"""Return the device class."""
return self._device_class
@property
def state(self):
"""Return the state of the device."""
return self._value
@property
def unit_of_measurement(self):
"""Return the unit of measurement."""
return self._unit
@property
def should_poll(self):
"""Return False because entity pushes its state."""
return False