Fix mysensors climate supported features (#15110)
This commit is contained in:
parent
9dd2c36de4
commit
b2d37ccef6
1 changed files with 16 additions and 6 deletions
|
@ -26,9 +26,8 @@ DICT_MYS_TO_HA = {
|
|||
'Off': STATE_OFF,
|
||||
}
|
||||
|
||||
SUPPORT_FLAGS = (SUPPORT_TARGET_TEMPERATURE | SUPPORT_TARGET_TEMPERATURE_HIGH |
|
||||
SUPPORT_TARGET_TEMPERATURE_LOW | SUPPORT_FAN_MODE |
|
||||
SUPPORT_OPERATION_MODE)
|
||||
FAN_LIST = ['Auto', 'Min', 'Normal', 'Max']
|
||||
OPERATION_LIST = [STATE_OFF, STATE_AUTO, STATE_COOL, STATE_HEAT]
|
||||
|
||||
|
||||
async def async_setup_platform(
|
||||
|
@ -45,7 +44,18 @@ class MySensorsHVAC(mysensors.device.MySensorsEntity, ClimateDevice):
|
|||
@property
|
||||
def supported_features(self):
|
||||
"""Return the list of supported features."""
|
||||
return SUPPORT_FLAGS
|
||||
features = SUPPORT_OPERATION_MODE
|
||||
set_req = self.gateway.const.SetReq
|
||||
if set_req.V_HVAC_SPEED in self._values:
|
||||
features = features | SUPPORT_FAN_MODE
|
||||
if (set_req.V_HVAC_SETPOINT_COOL in self._values and
|
||||
set_req.V_HVAC_SETPOINT_HEAT in self._values):
|
||||
features = (
|
||||
features | SUPPORT_TARGET_TEMPERATURE_HIGH |
|
||||
SUPPORT_TARGET_TEMPERATURE_LOW)
|
||||
else:
|
||||
features = features | SUPPORT_TARGET_TEMPERATURE
|
||||
return features
|
||||
|
||||
@property
|
||||
def assumed_state(self):
|
||||
|
@ -103,7 +113,7 @@ class MySensorsHVAC(mysensors.device.MySensorsEntity, ClimateDevice):
|
|||
@property
|
||||
def operation_list(self):
|
||||
"""List of available operation modes."""
|
||||
return [STATE_OFF, STATE_AUTO, STATE_COOL, STATE_HEAT]
|
||||
return OPERATION_LIST
|
||||
|
||||
@property
|
||||
def current_fan_mode(self):
|
||||
|
@ -113,7 +123,7 @@ class MySensorsHVAC(mysensors.device.MySensorsEntity, ClimateDevice):
|
|||
@property
|
||||
def fan_list(self):
|
||||
"""List of available fan modes."""
|
||||
return ['Auto', 'Min', 'Normal', 'Max']
|
||||
return FAN_LIST
|
||||
|
||||