Fix KNX climate.set_hvac_mode not turning on (#119012)

This commit is contained in:
Matthias Alphart 2024-06-06 22:40:04 +02:00 committed by GitHub
parent 7219a4fa98
commit a7429e5f50
No known key found for this signature in database
GPG key ID: B5690EEEBB952194
2 changed files with 10 additions and 5 deletions

View file

@ -283,16 +283,13 @@ class KNXClimate(KnxEntity, ClimateEntity):
)
if knx_controller_mode in self._device.mode.controller_modes:
await self._device.mode.set_controller_mode(knx_controller_mode)
self.async_write_ha_state()
return
if self._device.supports_on_off:
if hvac_mode == HVACMode.OFF:
await self._device.turn_off()
elif not self._device.is_on:
# for default hvac mode, otherwise above would have triggered
await self._device.turn_on()
self.async_write_ha_state()
self.async_write_ha_state()
@property