Fix ZHA creating unnecessary "summ received" entity after upgrade (#109268)
* Do not create `current_summ_received` entity until initialized once * Update zha_devices_list.py to not expect summation received entities The attribute isn't initialized for these devices in the test (which our check now expects it to be), hence we need to remove them from this list. * Update sensor tests to have initial state for current_summ_received entity The attribute needs to be initialized for it to be created which we do by plugging the attribute read. The test expects the initial state to be "unknown", but hence we plugged the attribute (to create the entity), the state is whatever we plug the attribute read as. * Update sensor tests to expect not updating current_summ_received entity if it doesn't exist
This commit is contained in:
parent
13bc018e23
commit
965f31a9e0
3 changed files with 43 additions and 58 deletions
|
@ -838,6 +838,26 @@ class SmartEnergySummationReceived(PolledSmartEnergySummation):
|
|||
_unique_id_suffix = "summation_received"
|
||||
_attr_translation_key: str = "summation_received"
|
||||
|
||||
@classmethod
|
||||
def create_entity(
|
||||
cls,
|
||||
unique_id: str,
|
||||
zha_device: ZHADevice,
|
||||
cluster_handlers: list[ClusterHandler],
|
||||
**kwargs: Any,
|
||||
) -> Self | None:
|
||||
"""Entity Factory.
|
||||
|
||||
This attribute only started to be initialized in HA 2024.2.0,
|
||||
so the entity would still be created on the first HA start after the upgrade for existing devices,
|
||||
as the initialization to see if an attribute is unsupported happens later in the background.
|
||||
To avoid creating a lot of unnecessary entities for existing devices,
|
||||
wait until the attribute was properly initialized once for now.
|
||||
"""
|
||||
if cluster_handlers[0].cluster.get(cls._attribute_name) is None:
|
||||
return None
|
||||
return super().create_entity(unique_id, zha_device, cluster_handlers, **kwargs)
|
||||
|
||||
|
||||
@MULTI_MATCH(cluster_handler_names=CLUSTER_HANDLER_PRESSURE)
|
||||
# pylint: disable-next=hass-invalid-inheritance # needs fixing
|
||||
|
|
|
@ -368,6 +368,7 @@ async def async_test_pi_heating_demand(hass, cluster, entity_id):
|
|||
"report_count",
|
||||
"read_plug",
|
||||
"unsupported_attrs",
|
||||
"initial_sensor_state",
|
||||
),
|
||||
(
|
||||
(
|
||||
|
@ -377,6 +378,7 @@ async def async_test_pi_heating_demand(hass, cluster, entity_id):
|
|||
1,
|
||||
None,
|
||||
None,
|
||||
STATE_UNKNOWN,
|
||||
),
|
||||
(
|
||||
measurement.TemperatureMeasurement.cluster_id,
|
||||
|
@ -385,6 +387,7 @@ async def async_test_pi_heating_demand(hass, cluster, entity_id):
|
|||
1,
|
||||
None,
|
||||
None,
|
||||
STATE_UNKNOWN,
|
||||
),
|
||||
(
|
||||
measurement.PressureMeasurement.cluster_id,
|
||||
|
@ -393,6 +396,7 @@ async def async_test_pi_heating_demand(hass, cluster, entity_id):
|
|||
1,
|
||||
None,
|
||||
None,
|
||||
STATE_UNKNOWN,
|
||||
),
|
||||
(
|
||||
measurement.IlluminanceMeasurement.cluster_id,
|
||||
|
@ -401,6 +405,7 @@ async def async_test_pi_heating_demand(hass, cluster, entity_id):
|
|||
1,
|
||||
None,
|
||||
None,
|
||||
STATE_UNKNOWN,
|
||||
),
|
||||
(
|
||||
smartenergy.Metering.cluster_id,
|
||||
|
@ -415,6 +420,7 @@ async def async_test_pi_heating_demand(hass, cluster, entity_id):
|
|||
"status": 0x00,
|
||||
},
|
||||
{"current_summ_delivered", "current_summ_received"},
|
||||
STATE_UNKNOWN,
|
||||
),
|
||||
(
|
||||
smartenergy.Metering.cluster_id,
|
||||
|
@ -431,6 +437,7 @@ async def async_test_pi_heating_demand(hass, cluster, entity_id):
|
|||
"unit_of_measure": 0x00,
|
||||
},
|
||||
{"instaneneous_demand", "current_summ_received"},
|
||||
STATE_UNKNOWN,
|
||||
),
|
||||
(
|
||||
smartenergy.Metering.cluster_id,
|
||||
|
@ -445,8 +452,10 @@ async def async_test_pi_heating_demand(hass, cluster, entity_id):
|
|||
"status": 0x00,
|
||||
"summation_formatting": 0b1_0111_010,
|
||||
"unit_of_measure": 0x00,
|
||||
"current_summ_received": 0,
|
||||
},
|
||||
{"instaneneous_demand", "current_summ_delivered"},
|
||||
"0.0",
|
||||
),
|
||||
(
|
||||
homeautomation.ElectricalMeasurement.cluster_id,
|
||||
|
@ -455,6 +464,7 @@ async def async_test_pi_heating_demand(hass, cluster, entity_id):
|
|||
7,
|
||||
{"ac_power_divisor": 1000, "ac_power_multiplier": 1},
|
||||
{"apparent_power", "rms_current", "rms_voltage"},
|
||||
STATE_UNKNOWN,
|
||||
),
|
||||
(
|
||||
homeautomation.ElectricalMeasurement.cluster_id,
|
||||
|
@ -463,6 +473,7 @@ async def async_test_pi_heating_demand(hass, cluster, entity_id):
|
|||
7,
|
||||
{"ac_power_divisor": 1000, "ac_power_multiplier": 1},
|
||||
{"active_power", "rms_current", "rms_voltage"},
|
||||
STATE_UNKNOWN,
|
||||
),
|
||||
(
|
||||
homeautomation.ElectricalMeasurement.cluster_id,
|
||||
|
@ -471,6 +482,7 @@ async def async_test_pi_heating_demand(hass, cluster, entity_id):
|
|||
7,
|
||||
{"ac_power_divisor": 1000, "ac_power_multiplier": 1},
|
||||
{"active_power", "apparent_power", "rms_current", "rms_voltage"},
|
||||
STATE_UNKNOWN,
|
||||
),
|
||||
(
|
||||
homeautomation.ElectricalMeasurement.cluster_id,
|
||||
|
@ -479,6 +491,7 @@ async def async_test_pi_heating_demand(hass, cluster, entity_id):
|
|||
7,
|
||||
{"ac_current_divisor": 1000, "ac_current_multiplier": 1},
|
||||
{"active_power", "apparent_power", "rms_voltage"},
|
||||
STATE_UNKNOWN,
|
||||
),
|
||||
(
|
||||
homeautomation.ElectricalMeasurement.cluster_id,
|
||||
|
@ -487,6 +500,7 @@ async def async_test_pi_heating_demand(hass, cluster, entity_id):
|
|||
7,
|
||||
{"ac_voltage_divisor": 10, "ac_voltage_multiplier": 1},
|
||||
{"active_power", "apparent_power", "rms_current"},
|
||||
STATE_UNKNOWN,
|
||||
),
|
||||
(
|
||||
general.PowerConfiguration.cluster_id,
|
||||
|
@ -499,6 +513,7 @@ async def async_test_pi_heating_demand(hass, cluster, entity_id):
|
|||
"battery_quantity": 3,
|
||||
},
|
||||
None,
|
||||
STATE_UNKNOWN,
|
||||
),
|
||||
(
|
||||
general.PowerConfiguration.cluster_id,
|
||||
|
@ -511,6 +526,7 @@ async def async_test_pi_heating_demand(hass, cluster, entity_id):
|
|||
"battery_quantity": 3,
|
||||
},
|
||||
None,
|
||||
STATE_UNKNOWN,
|
||||
),
|
||||
(
|
||||
general.DeviceTemperature.cluster_id,
|
||||
|
@ -519,6 +535,7 @@ async def async_test_pi_heating_demand(hass, cluster, entity_id):
|
|||
1,
|
||||
None,
|
||||
None,
|
||||
STATE_UNKNOWN,
|
||||
),
|
||||
(
|
||||
hvac.Thermostat.cluster_id,
|
||||
|
@ -527,6 +544,7 @@ async def async_test_pi_heating_demand(hass, cluster, entity_id):
|
|||
10,
|
||||
None,
|
||||
None,
|
||||
STATE_UNKNOWN,
|
||||
),
|
||||
(
|
||||
hvac.Thermostat.cluster_id,
|
||||
|
@ -535,6 +553,7 @@ async def async_test_pi_heating_demand(hass, cluster, entity_id):
|
|||
10,
|
||||
None,
|
||||
None,
|
||||
STATE_UNKNOWN,
|
||||
),
|
||||
),
|
||||
)
|
||||
|
@ -548,6 +567,7 @@ async def test_sensor(
|
|||
report_count,
|
||||
read_plug,
|
||||
unsupported_attrs,
|
||||
initial_sensor_state,
|
||||
) -> None:
|
||||
"""Test ZHA sensor platform."""
|
||||
|
||||
|
@ -582,8 +602,8 @@ async def test_sensor(
|
|||
# allow traffic to flow through the gateway and devices
|
||||
await async_enable_traffic(hass, [zha_device])
|
||||
|
||||
# test that the sensor now have a state of unknown
|
||||
assert hass.states.get(entity_id).state == STATE_UNKNOWN
|
||||
# test that the sensor now have their correct initial state (mostly unknown)
|
||||
assert hass.states.get(entity_id).state == initial_sensor_state
|
||||
|
||||
# test sensor associated logic
|
||||
await test_func(hass, cluster, entity_id)
|
||||
|
@ -826,7 +846,6 @@ async def test_electrical_measurement_init(
|
|||
},
|
||||
{
|
||||
"summation_delivered",
|
||||
"summation_received",
|
||||
},
|
||||
{
|
||||
"instantaneous_demand",
|
||||
|
@ -834,12 +853,11 @@ async def test_electrical_measurement_init(
|
|||
),
|
||||
(
|
||||
smartenergy.Metering.cluster_id,
|
||||
{"instantaneous_demand", "current_summ_delivered", "current_summ_received"},
|
||||
{"instantaneous_demand", "current_summ_delivered"},
|
||||
{},
|
||||
{
|
||||
"instantaneous_demand",
|
||||
"summation_delivered",
|
||||
"summation_received",
|
||||
},
|
||||
),
|
||||
(
|
||||
|
@ -848,7 +866,6 @@ async def test_electrical_measurement_init(
|
|||
{
|
||||
"instantaneous_demand",
|
||||
"summation_delivered",
|
||||
"summation_received",
|
||||
},
|
||||
{},
|
||||
),
|
||||
|
|
|
@ -243,11 +243,6 @@ DEVICES = [
|
|||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergySummation",
|
||||
DEV_SIG_ENT_MAP_ID: "sensor.centralite_3210_l_summation_delivered",
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-1794-summation_received"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["smartenergy_metering"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergySummation",
|
||||
DEV_SIG_ENT_MAP_ID: "sensor.centralite_3210_l_summation_received",
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-0-rssi"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["basic"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "RSSISensor",
|
||||
|
@ -616,13 +611,6 @@ DEVICES = [
|
|||
"sensor.climaxtechnology_psmp5_00_00_02_02tc_summation_delivered"
|
||||
),
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-1794-summation_received"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["smartenergy_metering"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergySummation",
|
||||
DEV_SIG_ENT_MAP_ID: (
|
||||
"sensor.climaxtechnology_psmp5_00_00_02_02tc_summation_received"
|
||||
),
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-0-rssi"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["basic"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "RSSISensor",
|
||||
|
@ -1617,11 +1605,6 @@ DEVICES = [
|
|||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergySummation",
|
||||
DEV_SIG_ENT_MAP_ID: "sensor.jasco_products_45852_summation_delivered",
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-1794-summation_received"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["smartenergy_metering"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergySummation",
|
||||
DEV_SIG_ENT_MAP_ID: "sensor.jasco_products_45852_summation_received",
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-0-rssi"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["basic"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "RSSISensor",
|
||||
|
@ -1682,11 +1665,6 @@ DEVICES = [
|
|||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergySummation",
|
||||
DEV_SIG_ENT_MAP_ID: "sensor.jasco_products_45856_summation_delivered",
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-1794-summation_received"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["smartenergy_metering"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergySummation",
|
||||
DEV_SIG_ENT_MAP_ID: "sensor.jasco_products_45856_summation_received",
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-0-rssi"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["basic"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "RSSISensor",
|
||||
|
@ -1747,11 +1725,6 @@ DEVICES = [
|
|||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergySummation",
|
||||
DEV_SIG_ENT_MAP_ID: "sensor.jasco_products_45857_summation_delivered",
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-1794-summation_received"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["smartenergy_metering"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergySummation",
|
||||
DEV_SIG_ENT_MAP_ID: "sensor.jasco_products_45857_summation_received",
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-0-rssi"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["basic"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "RSSISensor",
|
||||
|
@ -2370,11 +2343,6 @@ DEVICES = [
|
|||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergySummation",
|
||||
DEV_SIG_ENT_MAP_ID: "sensor.lumi_lumi_relay_c2acn01_summation_delivered",
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-1794-summation_received"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["smartenergy_metering"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergySummation",
|
||||
DEV_SIG_ENT_MAP_ID: "sensor.lumi_lumi_relay_c2acn01_summation_received",
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-1794"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["smartenergy_metering"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergyMetering",
|
||||
|
@ -4511,11 +4479,6 @@ DEVICES = [
|
|||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergySummation",
|
||||
DEV_SIG_ENT_MAP_ID: "sensor.sercomm_corp_sz_esw01_summation_delivered",
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-1794-summation_received"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["smartenergy_metering"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergySummation",
|
||||
DEV_SIG_ENT_MAP_ID: "sensor.sercomm_corp_sz_esw01_summation_received",
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-0-rssi"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["basic"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "RSSISensor",
|
||||
|
@ -5362,11 +5325,6 @@ DEVICES = [
|
|||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergySummation",
|
||||
DEV_SIG_ENT_MAP_ID: "sensor.sengled_e11_g13_summation_delivered",
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-1794-summation_received"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["smartenergy_metering"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergySummation",
|
||||
DEV_SIG_ENT_MAP_ID: "sensor.sengled_e11_g13_summation_received",
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-0-rssi"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["basic"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "RSSISensor",
|
||||
|
@ -5420,11 +5378,6 @@ DEVICES = [
|
|||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergySummation",
|
||||
DEV_SIG_ENT_MAP_ID: "sensor.sengled_e12_n14_summation_delivered",
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-1794-summation_received"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["smartenergy_metering"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergySummation",
|
||||
DEV_SIG_ENT_MAP_ID: "sensor.sengled_e12_n14_summation_received",
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-0-rssi"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["basic"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "RSSISensor",
|
||||
|
@ -5478,11 +5431,6 @@ DEVICES = [
|
|||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergySummation",
|
||||
DEV_SIG_ENT_MAP_ID: "sensor.sengled_z01_a19nae26_summation_delivered",
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-1794-summation_received"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["smartenergy_metering"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "SmartEnergySummation",
|
||||
DEV_SIG_ENT_MAP_ID: "sensor.sengled_z01_a19nae26_summation_received",
|
||||
},
|
||||
("sensor", "00:11:22:33:44:55:66:77-1-0-rssi"): {
|
||||
DEV_SIG_CLUSTER_HANDLERS: ["basic"],
|
||||
DEV_SIG_ENT_MAP_CLASS: "RSSISensor",
|
||||
|
|
Loading…
Add table