Add tuya zndb device category (#59477)

This commit is contained in:
Oleksandr Kapshuk 2021-12-01 14:17:02 +02:00 committed by GitHub
parent d5dc963b6f
commit 95286791fe
No known key found for this signature in database
GPG key ID: 4AEE18F83AFDEB23
4 changed files with 225 additions and 91 deletions

View file

@ -1,6 +1,7 @@
"""Support for Tuya sensors."""
from __future__ import annotations
from dataclasses import dataclass
from typing import cast
from tuya_iot import TuyaDevice, TuyaDeviceManager
@ -9,6 +10,7 @@ from tuya_iot.device import TuyaDeviceStatusRange
from homeassistant.components.sensor import (
DEVICE_CLASS_BATTERY,
STATE_CLASS_MEASUREMENT,
STATE_CLASS_TOTAL_INCREASING,
SensorEntity,
SensorEntityDescription,
)
@ -17,6 +19,7 @@ from homeassistant.const import (
DEVICE_CLASS_CO,
DEVICE_CLASS_CO2,
DEVICE_CLASS_CURRENT,
DEVICE_CLASS_ENERGY,
DEVICE_CLASS_HUMIDITY,
DEVICE_CLASS_ILLUMINANCE,
DEVICE_CLASS_PM1,
@ -27,8 +30,11 @@ from homeassistant.const import (
DEVICE_CLASS_TEMPERATURE,
DEVICE_CLASS_VOLATILE_ORGANIC_COMPOUNDS,
DEVICE_CLASS_VOLTAGE,
ELECTRIC_CURRENT_AMPERE,
ELECTRIC_POTENTIAL_VOLT,
ENTITY_CATEGORY_DIAGNOSTIC,
PERCENTAGE,
POWER_KILO_WATT,
)
from homeassistant.core import HomeAssistant, callback
from homeassistant.helpers.dispatcher import async_dispatcher_connect
@ -36,7 +42,7 @@ from homeassistant.helpers.entity_platform import AddEntitiesCallback
from homeassistant.helpers.typing import StateType
from . import HomeAssistantTuyaData
from .base import EnumTypeData, IntegerTypeData, TuyaEntity
from .base import ElectricityTypeData, EnumTypeData, IntegerTypeData, TuyaEntity
from .const import (
DEVICE_CLASS_TUYA_STATUS,
DEVICE_CLASS_UNITS,
@ -46,9 +52,17 @@ from .const import (
UnitOfMeasurement,
)
@dataclass
class TuyaSensorEntityDescription(SensorEntityDescription):
"""Describes Tuya sensor entity."""
subkey: str | None = None
# Commonly used battery sensors, that are re-used in the sensors down below.
BATTERY_SENSORS: tuple[SensorEntityDescription, ...] = (
SensorEntityDescription(
BATTERY_SENSORS: tuple[TuyaSensorEntityDescription, ...] = (
TuyaSensorEntityDescription(
key=DPCode.BATTERY_PERCENTAGE,
name="Battery",
native_unit_of_measurement=PERCENTAGE,
@ -56,20 +70,20 @@ BATTERY_SENSORS: tuple[SensorEntityDescription, ...] = (
state_class=STATE_CLASS_MEASUREMENT,
entity_category=ENTITY_CATEGORY_DIAGNOSTIC,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.BATTERY_STATE,
name="Battery State",
icon="mdi:battery",
entity_category=ENTITY_CATEGORY_DIAGNOSTIC,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.BATTERY_VALUE,
name="Battery",
device_class=DEVICE_CLASS_BATTERY,
entity_category=ENTITY_CATEGORY_DIAGNOSTIC,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.VA_BATTERY,
name="Battery",
device_class=DEVICE_CLASS_BATTERY,
@ -82,23 +96,23 @@ BATTERY_SENSORS: tuple[SensorEntityDescription, ...] = (
# default status set of each category (that don't have a set instruction)
# end up being a sensor.
# https://developer.tuya.com/en/docs/iot/standarddescription?id=K9i5ql6waswzq
SENSORS: dict[str, tuple[SensorEntityDescription, ...]] = {
SENSORS: dict[str, tuple[TuyaSensorEntityDescription, ...]] = {
# Smart Kettle
# https://developer.tuya.com/en/docs/iot/fbh?id=K9gf484m21yq7
"bh": (
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.TEMP_CURRENT,
name="Current Temperature",
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.TEMP_CURRENT_F,
name="Current Temperature",
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.STATUS,
name="Status",
device_class=DEVICE_CLASS_TUYA_STATUS,
@ -107,19 +121,19 @@ SENSORS: dict[str, tuple[SensorEntityDescription, ...]] = {
# CO2 Detector
# https://developer.tuya.com/en/docs/iot/categoryco2bj?id=Kaiuz3wes7yuy
"co2bj": (
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.HUMIDITY_VALUE,
name="Humidity",
device_class=DEVICE_CLASS_HUMIDITY,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.TEMP_CURRENT,
name="Temperature",
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.CO2_VALUE,
name="Carbon Dioxide",
device_class=DEVICE_CLASS_CO2,
@ -130,7 +144,7 @@ SENSORS: dict[str, tuple[SensorEntityDescription, ...]] = {
# CO Detector
# https://developer.tuya.com/en/docs/iot/categorycobj?id=Kaiuz3u1j6q1v
"cobj": (
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.CO_VALUE,
name="Carbon Monoxide",
device_class=DEVICE_CLASS_CO,
@ -141,101 +155,76 @@ SENSORS: dict[str, tuple[SensorEntityDescription, ...]] = {
# Air Quality Monitor
# No specification on Tuya portal
"hjjcy": (
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.TEMP_CURRENT,
name="Temperature",
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.HUMIDITY_VALUE,
name="Humidity",
device_class=DEVICE_CLASS_HUMIDITY,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.CO2_VALUE,
name="Carbon Dioxide",
device_class=DEVICE_CLASS_CO2,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.CH2O_VALUE,
name="Formaldehyde",
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.VOC_VALUE,
name="Volatile Organic Compound",
device_class=DEVICE_CLASS_VOLATILE_ORGANIC_COMPOUNDS,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.PM25_VALUE,
name="Particulate Matter 2.5 µm",
device_class=DEVICE_CLASS_PM25,
state_class=STATE_CLASS_MEASUREMENT,
),
),
# Switch
# https://developer.tuya.com/en/docs/iot/s?id=K9gf7o5prgf7s
"kg": (
SensorEntityDescription(
key=DPCode.CUR_CURRENT,
name="Current",
device_class=DEVICE_CLASS_CURRENT,
state_class=STATE_CLASS_MEASUREMENT,
entity_registry_enabled_default=False,
),
SensorEntityDescription(
key=DPCode.CUR_POWER,
name="Power",
device_class=DEVICE_CLASS_POWER,
state_class=STATE_CLASS_MEASUREMENT,
entity_registry_enabled_default=False,
),
SensorEntityDescription(
key=DPCode.CUR_VOLTAGE,
name="Voltage",
device_class=DEVICE_CLASS_VOLTAGE,
state_class=STATE_CLASS_MEASUREMENT,
entity_registry_enabled_default=False,
),
),
# Formaldehyde Detector
# Note: Not documented
"jqbj": (
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.CO2_VALUE,
name="Carbon Dioxide",
device_class=DEVICE_CLASS_CO2,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.VOC_VALUE,
name="Volatile Organic Compound",
device_class=DEVICE_CLASS_VOLATILE_ORGANIC_COMPOUNDS,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.PM25_VALUE,
name="Particulate Matter 2.5 µm",
device_class=DEVICE_CLASS_PM25,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.VA_HUMIDITY,
name="Humidity",
device_class=DEVICE_CLASS_HUMIDITY,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.VA_TEMPERATURE,
name="Temperature",
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.CH2O_VALUE,
name="Formaldehyde",
state_class=STATE_CLASS_MEASUREMENT,
@ -245,40 +234,65 @@ SENSORS: dict[str, tuple[SensorEntityDescription, ...]] = {
# Methane Detector
# https://developer.tuya.com/en/docs/iot/categoryjwbj?id=Kaiuz40u98lkm
"jwbj": (
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.CH4_SENSOR_VALUE,
name="Methane",
state_class=STATE_CLASS_MEASUREMENT,
),
*BATTERY_SENSORS,
),
# Switch
# https://developer.tuya.com/en/docs/iot/s?id=K9gf7o5prgf7s
"kg": (
TuyaSensorEntityDescription(
key=DPCode.CUR_CURRENT,
name="Current",
device_class=DEVICE_CLASS_CURRENT,
state_class=STATE_CLASS_MEASUREMENT,
entity_registry_enabled_default=False,
),
TuyaSensorEntityDescription(
key=DPCode.CUR_POWER,
name="Power",
device_class=DEVICE_CLASS_POWER,
state_class=STATE_CLASS_MEASUREMENT,
entity_registry_enabled_default=False,
),
TuyaSensorEntityDescription(
key=DPCode.CUR_VOLTAGE,
name="Voltage",
device_class=DEVICE_CLASS_VOLTAGE,
state_class=STATE_CLASS_MEASUREMENT,
entity_registry_enabled_default=False,
),
),
# Luminance Sensor
# https://developer.tuya.com/en/docs/iot/categoryldcg?id=Kaiuz3n7u69l8
"ldcg": (
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.BRIGHT_STATE,
name="Luminosity",
icon="mdi:brightness-6",
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.BRIGHT_VALUE,
name="Luminosity",
device_class=DEVICE_CLASS_ILLUMINANCE,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.TEMP_CURRENT,
name="Temperature",
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.HUMIDITY_VALUE,
name="Humidity",
device_class=DEVICE_CLASS_HUMIDITY,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.CO2_VALUE,
name="Carbon Dioxide",
device_class=DEVICE_CLASS_CO2,
@ -295,48 +309,48 @@ SENSORS: dict[str, tuple[SensorEntityDescription, ...]] = {
# PM2.5 Sensor
# https://developer.tuya.com/en/docs/iot/categorypm25?id=Kaiuz3qof3yfu
"pm2.5": (
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.PM25_VALUE,
name="Particulate Matter 2.5 µm",
device_class=DEVICE_CLASS_PM25,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.CH2O_VALUE,
name="Formaldehyde",
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.VOC_VALUE,
name="Volatile Organic Compound",
device_class=DEVICE_CLASS_VOLATILE_ORGANIC_COMPOUNDS,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.TEMP_CURRENT,
name="Temperature",
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.CO2_VALUE,
name="Carbon Dioxide",
device_class=DEVICE_CLASS_CO2,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.HUMIDITY_VALUE,
name="Humidity",
device_class=DEVICE_CLASS_HUMIDITY,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.PM1,
name="Particulate Matter 1.0 µm",
device_class=DEVICE_CLASS_PM1,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.PM10,
name="Particulate Matter 10.0 µm",
device_class=DEVICE_CLASS_PM10,
@ -347,7 +361,7 @@ SENSORS: dict[str, tuple[SensorEntityDescription, ...]] = {
# Heater
# https://developer.tuya.com/en/docs/iot/categoryqn?id=Kaiuz18kih0sm
"qn": (
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.WORK_POWER,
name="Power",
device_class=DEVICE_CLASS_POWER,
@ -357,7 +371,7 @@ SENSORS: dict[str, tuple[SensorEntityDescription, ...]] = {
# Gas Detector
# https://developer.tuya.com/en/docs/iot/categoryrqbj?id=Kaiuz3d162ubw
"rqbj": (
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.GAS_SENSOR_VALUE,
icon="mdi:gas-cylinder",
device_class=STATE_CLASS_MEASUREMENT,
@ -373,19 +387,19 @@ SENSORS: dict[str, tuple[SensorEntityDescription, ...]] = {
# Smart Camera
# https://developer.tuya.com/en/docs/iot/categorysp?id=Kaiuz35leyo12
"sp": (
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.SENSOR_TEMPERATURE,
name="Temperature",
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.SENSOR_HUMIDITY,
name="Humidity",
device_class=DEVICE_CLASS_HUMIDITY,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.WIRELESS_ELECTRICITY,
name="Battery",
device_class=DEVICE_CLASS_BATTERY,
@ -393,42 +407,44 @@ SENSORS: dict[str, tuple[SensorEntityDescription, ...]] = {
state_class=STATE_CLASS_MEASUREMENT,
),
),
# Fingerbot
"szjqr": BATTERY_SENSORS,
# Solar Light
# https://developer.tuya.com/en/docs/iot/tynd?id=Kaof8j02e1t98
"tyndj": BATTERY_SENSORS,
# Volatile Organic Compound Sensor
# Note: Undocumented in cloud API docs, based on test device
"voc": (
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.CO2_VALUE,
name="Carbon Dioxide",
device_class=DEVICE_CLASS_CO2,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.PM25_VALUE,
name="Particulate Matter 2.5 µm",
device_class=DEVICE_CLASS_PM25,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.CH2O_VALUE,
name="Formaldehyde",
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.HUMIDITY_VALUE,
name="Humidity",
device_class=DEVICE_CLASS_HUMIDITY,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.TEMP_CURRENT,
name="Temperature",
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.VOC_VALUE,
name="Volatile Organic Compound",
device_class=DEVICE_CLASS_VOLATILE_ORGANIC_COMPOUNDS,
@ -439,31 +455,31 @@ SENSORS: dict[str, tuple[SensorEntityDescription, ...]] = {
# Temperature and Humidity Sensor
# https://developer.tuya.com/en/docs/iot/categorywsdcg?id=Kaiuz3hinij34
"wsdcg": (
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.VA_TEMPERATURE,
name="Temperature",
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.TEMP_CURRENT,
name="Temperature",
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.VA_HUMIDITY,
name="Humidity",
device_class=DEVICE_CLASS_HUMIDITY,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.HUMIDITY_VALUE,
name="Humidity",
device_class=DEVICE_CLASS_HUMIDITY,
state_class=STATE_CLASS_MEASUREMENT,
),
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.BRIGHT_VALUE,
name="Luminosity",
device_class=DEVICE_CLASS_ILLUMINANCE,
@ -474,7 +490,7 @@ SENSORS: dict[str, tuple[SensorEntityDescription, ...]] = {
# Pressure Sensor
# https://developer.tuya.com/en/docs/iot/categoryylcg?id=Kaiuz3kc2e4gm
"ylcg": (
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.PRESSURE_VALUE,
device_class=DEVICE_CLASS_PRESSURE,
state_class=STATE_CLASS_MEASUREMENT,
@ -484,7 +500,7 @@ SENSORS: dict[str, tuple[SensorEntityDescription, ...]] = {
# Smoke Detector
# https://developer.tuya.com/en/docs/iot/categoryywbj?id=Kaiuz3f6sf952
"ywbj": (
SensorEntityDescription(
TuyaSensorEntityDescription(
key=DPCode.SMOKE_SENSOR_VALUE,
name="Smoke Amount",
icon="mdi:smoke-detector",
@ -496,8 +512,88 @@ SENSORS: dict[str, tuple[SensorEntityDescription, ...]] = {
# Vibration Sensor
# https://developer.tuya.com/en/docs/iot/categoryzd?id=Kaiuz3a5vrzno
"zd": BATTERY_SENSORS,
# Fingerbot
"szjqr": BATTERY_SENSORS,
# Smart Electricity Meter
# https://developer.tuya.com/en/docs/iot/smart-meter?id=Kaiuz4gv6ack7
"zndb": (
TuyaSensorEntityDescription(
key=DPCode.FORWARD_ENERGY_TOTAL,
name="Total Energy",
device_class=DEVICE_CLASS_ENERGY,
state_class=STATE_CLASS_TOTAL_INCREASING,
),
TuyaSensorEntityDescription(
key=DPCode.PHASE_A,
name="Phase A Current",
device_class=DEVICE_CLASS_CURRENT,
native_unit_of_measurement=ELECTRIC_CURRENT_AMPERE,
state_class=STATE_CLASS_MEASUREMENT,
subkey="electriccurrent",
),
TuyaSensorEntityDescription(
key=DPCode.PHASE_A,
name="Phase A Power",
device_class=DEVICE_CLASS_POWER,
state_class=STATE_CLASS_MEASUREMENT,
native_unit_of_measurement=POWER_KILO_WATT,
subkey="power",
),
TuyaSensorEntityDescription(
key=DPCode.PHASE_A,
name="Phase A Voltage",
device_class=DEVICE_CLASS_VOLTAGE,
state_class=STATE_CLASS_MEASUREMENT,
native_unit_of_measurement=ELECTRIC_POTENTIAL_VOLT,
subkey="voltage",
),
TuyaSensorEntityDescription(
key=DPCode.PHASE_B,
name="Phase B Current",
device_class=DEVICE_CLASS_CURRENT,
native_unit_of_measurement=ELECTRIC_CURRENT_AMPERE,
state_class=STATE_CLASS_MEASUREMENT,
subkey="electriccurrent",
),
TuyaSensorEntityDescription(
key=DPCode.PHASE_B,
name="Phase B Power",
device_class=DEVICE_CLASS_POWER,
state_class=STATE_CLASS_MEASUREMENT,
native_unit_of_measurement=POWER_KILO_WATT,
subkey="power",
),
TuyaSensorEntityDescription(
key=DPCode.PHASE_B,
name="Phase B Voltage",
device_class=DEVICE_CLASS_VOLTAGE,
state_class=STATE_CLASS_MEASUREMENT,
native_unit_of_measurement=ELECTRIC_POTENTIAL_VOLT,
subkey="voltage",
),
TuyaSensorEntityDescription(
key=DPCode.PHASE_C,
name="Phase C Current",
device_class=DEVICE_CLASS_CURRENT,
native_unit_of_measurement=ELECTRIC_CURRENT_AMPERE,
state_class=STATE_CLASS_MEASUREMENT,
subkey="electriccurrent",
),
TuyaSensorEntityDescription(
key=DPCode.PHASE_C,
name="Phase C Power",
device_class=DEVICE_CLASS_POWER,
state_class=STATE_CLASS_MEASUREMENT,
native_unit_of_measurement=POWER_KILO_WATT,
subkey="power",
),
TuyaSensorEntityDescription(
key=DPCode.PHASE_C,
name="Phase C Voltage",
device_class=DEVICE_CLASS_VOLTAGE,
state_class=STATE_CLASS_MEASUREMENT,
native_unit_of_measurement=ELECTRIC_POTENTIAL_VOLT,
subkey="voltage",
),
),
}
# Socket (duplicate of `kg`)
@ -545,6 +641,8 @@ async def async_setup_entry(
class TuyaSensorEntity(TuyaEntity, SensorEntity):
"""Tuya Sensor Entity."""
entity_description: TuyaSensorEntityDescription
_status_range: TuyaDeviceStatusRange | None = None
_type_data: IntegerTypeData | EnumTypeData | None = None
_uom: UnitOfMeasurement | None = None
@ -553,12 +651,14 @@ class TuyaSensorEntity(TuyaEntity, SensorEntity):
self,
device: TuyaDevice,
device_manager: TuyaDeviceManager,
description: SensorEntityDescription,
description: TuyaSensorEntityDescription,
) -> None:
"""Init Tuya sensor."""
super().__init__(device, device_manager)
self.entity_description = description
self._attr_unique_id = f"{super().unique_id}{description.key}"
self._attr_unique_id = (
f"{super().unique_id}{description.key}{description.subkey or ''}"
)
if status_range := device.status_range.get(description.key):
self._status_range = cast(TuyaDeviceStatusRange, status_range)
@ -614,6 +714,7 @@ class TuyaSensorEntity(TuyaEntity, SensorEntity):
"Integer",
"String",
"Enum",
"Json",
):
return None
@ -636,5 +737,12 @@ class TuyaSensorEntity(TuyaEntity, SensorEntity):
):
return None
# Get subkey value from Json string.
if self._status_range.type == "Json":
if self.entity_description.subkey is None:
return None
values = ElectricityTypeData.from_json(value)
return getattr(values, self.entity_description.subkey)
# Valid string or enum value
return value