Add sensor support to opentherm_gw (#17314)
* Add OpenTherm Gateway sensor platform.
* Add OTGW_ variables to list of supported sensors.
* Order imports.
* Add OpenTherm Gateway binary sensor support.
* Revert "Add OpenTherm Gateway binary sensor support."
This reverts commit 115acaa912
.
* Import COMP_SENSOR from sensor component rather than defining it.
* Update opentherm_gw sensor platform docs url.
* Update dependency to v0.2b1
Old version had incorrect variable names for some of the sensors
* Update requirements_all.txt
* Address review findings.
* Update .coveragerc
This commit is contained in:
parent
cc4d29d42a
commit
7baffed7b7
4 changed files with 304 additions and 5 deletions
|
@ -249,7 +249,7 @@ omit =
|
|||
homeassistant/components/*/opencv.py
|
||||
|
||||
homeassistant/components/opentherm_gw.py
|
||||
homeassistant/components/climate/opentherm_gw.py
|
||||
homeassistant/components/*/opentherm_gw.py
|
||||
|
||||
homeassistant/components/openuv/__init__.py
|
||||
homeassistant/components/*/openuv.py
|
||||
|
|
|
@ -8,8 +8,10 @@ import logging
|
|||
|
||||
import voluptuous as vol
|
||||
|
||||
from homeassistant.const import (CONF_DEVICE, CONF_NAME, PRECISION_HALVES,
|
||||
PRECISION_TENTHS, PRECISION_WHOLE)
|
||||
from homeassistant.components.sensor import DOMAIN as COMP_SENSOR
|
||||
from homeassistant.const import (CONF_DEVICE, CONF_MONITORED_VARIABLES,
|
||||
CONF_NAME, PRECISION_HALVES, PRECISION_TENTHS,
|
||||
PRECISION_WHOLE)
|
||||
from homeassistant.helpers.discovery import async_load_platform
|
||||
from homeassistant.helpers.dispatcher import async_dispatcher_send
|
||||
|
||||
|
@ -38,10 +40,12 @@ CONFIG_SCHEMA = vol.Schema({
|
|||
DOMAIN: vol.Schema({
|
||||
vol.Required(CONF_DEVICE): cv.string,
|
||||
vol.Optional(CONF_CLIMATE, default={}): CLIMATE_SCHEMA,
|
||||
vol.Optional(CONF_MONITORED_VARIABLES, default=[]): vol.All(
|
||||
cv.ensure_list, [cv.string]),
|
||||
}),
|
||||
}, extra=vol.ALLOW_EXTRA)
|
||||
|
||||
REQUIREMENTS = ['pyotgw==0.1b0']
|
||||
REQUIREMENTS = ['pyotgw==0.2b1']
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
|
@ -59,6 +63,8 @@ async def async_setup(hass, config):
|
|||
hass, conf[CONF_DEVICE], gateway))
|
||||
hass.async_create_task(async_load_platform(
|
||||
hass, 'climate', DOMAIN, conf.get(CONF_CLIMATE)))
|
||||
hass.async_create_task(setup_monitored_vars(
|
||||
hass, conf.get(CONF_MONITORED_VARIABLES)))
|
||||
return True
|
||||
|
||||
|
||||
|
@ -72,3 +78,85 @@ async def connect_and_subscribe(hass, device_path, gateway):
|
|||
_LOGGER.debug("Received report: %s", status)
|
||||
async_dispatcher_send(hass, SIGNAL_OPENTHERM_GW_UPDATE, status)
|
||||
gateway.subscribe(handle_report)
|
||||
|
||||
|
||||
async def setup_monitored_vars(hass, monitored_vars):
|
||||
"""Set up requested sensors."""
|
||||
gw_vars = hass.data[DATA_OPENTHERM_GW][DATA_GW_VARS]
|
||||
# Use dict to prepare for binary sensor support.
|
||||
sensor_type_map = {
|
||||
COMP_SENSOR: [
|
||||
gw_vars.DATA_CONTROL_SETPOINT,
|
||||
gw_vars.DATA_MASTER_MEMBERID,
|
||||
gw_vars.DATA_SLAVE_MEMBERID,
|
||||
gw_vars.DATA_SLAVE_OEM_FAULT,
|
||||
gw_vars.DATA_COOLING_CONTROL,
|
||||
gw_vars.DATA_CONTROL_SETPOINT_2,
|
||||
gw_vars.DATA_ROOM_SETPOINT_OVRD,
|
||||
gw_vars.DATA_SLAVE_MAX_RELATIVE_MOD,
|
||||
gw_vars.DATA_SLAVE_MAX_CAPACITY,
|
||||
gw_vars.DATA_SLAVE_MIN_MOD_LEVEL,
|
||||
gw_vars.DATA_ROOM_SETPOINT,
|
||||
gw_vars.DATA_REL_MOD_LEVEL,
|
||||
gw_vars.DATA_CH_WATER_PRESS,
|
||||
gw_vars.DATA_DHW_FLOW_RATE,
|
||||
gw_vars.DATA_ROOM_SETPOINT_2,
|
||||
gw_vars.DATA_ROOM_TEMP,
|
||||
gw_vars.DATA_CH_WATER_TEMP,
|
||||
gw_vars.DATA_DHW_TEMP,
|
||||
gw_vars.DATA_OUTSIDE_TEMP,
|
||||
gw_vars.DATA_RETURN_WATER_TEMP,
|
||||
gw_vars.DATA_SOLAR_STORAGE_TEMP,
|
||||
gw_vars.DATA_SOLAR_COLL_TEMP,
|
||||
gw_vars.DATA_CH_WATER_TEMP_2,
|
||||
gw_vars.DATA_DHW_TEMP_2,
|
||||
gw_vars.DATA_EXHAUST_TEMP,
|
||||
gw_vars.DATA_SLAVE_DHW_MAX_SETP,
|
||||
gw_vars.DATA_SLAVE_DHW_MIN_SETP,
|
||||
gw_vars.DATA_SLAVE_CH_MAX_SETP,
|
||||
gw_vars.DATA_SLAVE_CH_MIN_SETP,
|
||||
gw_vars.DATA_DHW_SETPOINT,
|
||||
gw_vars.DATA_MAX_CH_SETPOINT,
|
||||
gw_vars.DATA_OEM_DIAG,
|
||||
gw_vars.DATA_TOTAL_BURNER_STARTS,
|
||||
gw_vars.DATA_CH_PUMP_STARTS,
|
||||
gw_vars.DATA_DHW_PUMP_STARTS,
|
||||
gw_vars.DATA_DHW_BURNER_STARTS,
|
||||
gw_vars.DATA_TOTAL_BURNER_HOURS,
|
||||
gw_vars.DATA_CH_PUMP_HOURS,
|
||||
gw_vars.DATA_DHW_PUMP_HOURS,
|
||||
gw_vars.DATA_DHW_BURNER_HOURS,
|
||||
gw_vars.DATA_MASTER_OT_VERSION,
|
||||
gw_vars.DATA_SLAVE_OT_VERSION,
|
||||
gw_vars.DATA_MASTER_PRODUCT_TYPE,
|
||||
gw_vars.DATA_MASTER_PRODUCT_VERSION,
|
||||
gw_vars.DATA_SLAVE_PRODUCT_TYPE,
|
||||
gw_vars.DATA_SLAVE_PRODUCT_VERSION,
|
||||
gw_vars.OTGW_MODE,
|
||||
gw_vars.OTGW_DHW_OVRD,
|
||||
gw_vars.OTGW_ABOUT,
|
||||
gw_vars.OTGW_BUILD,
|
||||
gw_vars.OTGW_CLOCKMHZ,
|
||||
gw_vars.OTGW_LED_A,
|
||||
gw_vars.OTGW_LED_B,
|
||||
gw_vars.OTGW_LED_C,
|
||||
gw_vars.OTGW_LED_D,
|
||||
gw_vars.OTGW_LED_E,
|
||||
gw_vars.OTGW_LED_F,
|
||||
gw_vars.OTGW_GPIO_A,
|
||||
gw_vars.OTGW_GPIO_B,
|
||||
gw_vars.OTGW_SB_TEMP,
|
||||
gw_vars.OTGW_SETP_OVRD_MODE,
|
||||
gw_vars.OTGW_SMART_PWR,
|
||||
gw_vars.OTGW_THRM_DETECT,
|
||||
gw_vars.OTGW_VREF,
|
||||
]
|
||||
}
|
||||
sensors = []
|
||||
for var in monitored_vars:
|
||||
if var in sensor_type_map[COMP_SENSOR]:
|
||||
sensors.append(var)
|
||||
else:
|
||||
_LOGGER.error("Monitored variable not supported: %s", var)
|
||||
if sensors:
|
||||
await async_load_platform(hass, COMP_SENSOR, DOMAIN, sensors)
|
||||
|
|
211
homeassistant/components/sensor/opentherm_gw.py
Normal file
211
homeassistant/components/sensor/opentherm_gw.py
Normal file
|
@ -0,0 +1,211 @@
|
|||
"""
|
||||
Support for OpenTherm Gateway sensors.
|
||||
|
||||
For more details about this platform, please refer to the documentation at
|
||||
http://home-assistant.io/components/sensor.opentherm_gw/
|
||||
"""
|
||||
import logging
|
||||
|
||||
from homeassistant.components.opentherm_gw import (
|
||||
DATA_GW_VARS, DATA_OPENTHERM_GW, SIGNAL_OPENTHERM_GW_UPDATE)
|
||||
from homeassistant.components.sensor import ENTITY_ID_FORMAT
|
||||
from homeassistant.const import DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS
|
||||
from homeassistant.helpers.dispatcher import async_dispatcher_connect
|
||||
from homeassistant.helpers.entity import Entity, async_generate_entity_id
|
||||
|
||||
UNIT_BAR = 'bar'
|
||||
UNIT_HOUR = 'h'
|
||||
UNIT_KW = 'kW'
|
||||
UNIT_L_MIN = 'L/min'
|
||||
UNIT_PERCENT = '%'
|
||||
|
||||
DEPENDENCIES = ['opentherm_gw']
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
|
||||
async def async_setup_platform(hass, config, async_add_entities,
|
||||
discovery_info=None):
|
||||
"""Set up the OpenTherm Gateway sensors."""
|
||||
if discovery_info is None:
|
||||
return
|
||||
gw_vars = hass.data[DATA_OPENTHERM_GW][DATA_GW_VARS]
|
||||
sensor_info = {
|
||||
# [device_class, unit, friendly_name]
|
||||
gw_vars.DATA_CONTROL_SETPOINT: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Control Setpoint"],
|
||||
gw_vars.DATA_MASTER_MEMBERID: [None, None, "Thermostat Member ID"],
|
||||
gw_vars.DATA_SLAVE_MEMBERID: [None, None, "Boiler Member ID"],
|
||||
gw_vars.DATA_SLAVE_OEM_FAULT: [None, None, "Boiler OEM Fault Code"],
|
||||
gw_vars.DATA_COOLING_CONTROL: [
|
||||
None, UNIT_PERCENT, "Cooling Control Signal"],
|
||||
gw_vars.DATA_CONTROL_SETPOINT_2: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Control Setpoint 2"],
|
||||
gw_vars.DATA_ROOM_SETPOINT_OVRD: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Room Setpoint Override"],
|
||||
gw_vars.DATA_SLAVE_MAX_RELATIVE_MOD: [
|
||||
None, UNIT_PERCENT, "Boiler Maximum Relative Modulation"],
|
||||
gw_vars.DATA_SLAVE_MAX_CAPACITY: [
|
||||
None, UNIT_KW, "Boiler Maximum Capacity"],
|
||||
gw_vars.DATA_SLAVE_MIN_MOD_LEVEL: [
|
||||
None, UNIT_PERCENT, "Boiler Minimum Modulation Level"],
|
||||
gw_vars.DATA_ROOM_SETPOINT: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Room Setpoint"],
|
||||
gw_vars.DATA_REL_MOD_LEVEL: [
|
||||
None, UNIT_PERCENT, "Relative Modulation Level"],
|
||||
gw_vars.DATA_CH_WATER_PRESS: [
|
||||
None, UNIT_BAR, "Central Heating Water Pressure"],
|
||||
gw_vars.DATA_DHW_FLOW_RATE: [None, UNIT_L_MIN, "Hot Water Flow Rate"],
|
||||
gw_vars.DATA_ROOM_SETPOINT_2: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Room Setpoint 2"],
|
||||
gw_vars.DATA_ROOM_TEMP: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Room Temperature"],
|
||||
gw_vars.DATA_CH_WATER_TEMP: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
|
||||
"Central Heating Water Temperature"],
|
||||
gw_vars.DATA_DHW_TEMP: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Hot Water Temperature"],
|
||||
gw_vars.DATA_OUTSIDE_TEMP: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Outside Temperature"],
|
||||
gw_vars.DATA_RETURN_WATER_TEMP: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
|
||||
"Return Water Temperature"],
|
||||
gw_vars.DATA_SOLAR_STORAGE_TEMP: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
|
||||
"Solar Storage Temperature"],
|
||||
gw_vars.DATA_SOLAR_COLL_TEMP: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
|
||||
"Solar Collector Temperature"],
|
||||
gw_vars.DATA_CH_WATER_TEMP_2: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
|
||||
"Central Heating 2 Water Temperature"],
|
||||
gw_vars.DATA_DHW_TEMP_2: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Hot Water 2 Temperature"],
|
||||
gw_vars.DATA_EXHAUST_TEMP: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Exhaust Temperature"],
|
||||
gw_vars.DATA_SLAVE_DHW_MAX_SETP: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
|
||||
"Hot Water Maximum Setpoint"],
|
||||
gw_vars.DATA_SLAVE_DHW_MIN_SETP: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
|
||||
"Hot Water Minimum Setpoint"],
|
||||
gw_vars.DATA_SLAVE_CH_MAX_SETP: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
|
||||
"Boiler Maximum Central Heating Setpoint"],
|
||||
gw_vars.DATA_SLAVE_CH_MIN_SETP: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
|
||||
"Boiler Minimum Central Heating Setpoint"],
|
||||
gw_vars.DATA_DHW_SETPOINT: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Hot Water Setpoint"],
|
||||
gw_vars.DATA_MAX_CH_SETPOINT: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
|
||||
"Maximum Central Heating Setpoint"],
|
||||
gw_vars.DATA_OEM_DIAG: [None, None, "OEM Diagnostic Code"],
|
||||
gw_vars.DATA_TOTAL_BURNER_STARTS: [
|
||||
None, None, "Total Burner Starts"],
|
||||
gw_vars.DATA_CH_PUMP_STARTS: [
|
||||
None, None, "Central Heating Pump Starts"],
|
||||
gw_vars.DATA_DHW_PUMP_STARTS: [None, None, "Hot Water Pump Starts"],
|
||||
gw_vars.DATA_DHW_BURNER_STARTS: [
|
||||
None, None, "Hot Water Burner Starts"],
|
||||
gw_vars.DATA_TOTAL_BURNER_HOURS: [
|
||||
None, UNIT_HOUR, "Total Burner Hours"],
|
||||
gw_vars.DATA_CH_PUMP_HOURS: [
|
||||
None, UNIT_HOUR, "Central Heating Pump Hours"],
|
||||
gw_vars.DATA_DHW_PUMP_HOURS: [None, UNIT_HOUR, "Hot Water Pump Hours"],
|
||||
gw_vars.DATA_DHW_BURNER_HOURS: [
|
||||
None, UNIT_HOUR, "Hot Water Burner Hours"],
|
||||
gw_vars.DATA_MASTER_OT_VERSION: [
|
||||
None, None, "Thermostat OpenTherm Version"],
|
||||
gw_vars.DATA_SLAVE_OT_VERSION: [
|
||||
None, None, "Boiler OpenTherm Version"],
|
||||
gw_vars.DATA_MASTER_PRODUCT_TYPE: [
|
||||
None, None, "Thermostat Product Type"],
|
||||
gw_vars.DATA_MASTER_PRODUCT_VERSION: [
|
||||
None, None, "Thermostat Product Version"],
|
||||
gw_vars.DATA_SLAVE_PRODUCT_TYPE: [None, None, "Boiler Product Type"],
|
||||
gw_vars.DATA_SLAVE_PRODUCT_VERSION: [
|
||||
None, None, "Boiler Product Version"],
|
||||
gw_vars.OTGW_MODE: [None, None, "Gateway/Monitor Mode"],
|
||||
gw_vars.OTGW_DHW_OVRD: [None, None, "Gateway Hot Water Override Mode"],
|
||||
gw_vars.OTGW_ABOUT: [None, None, "Gateway Firmware Version"],
|
||||
gw_vars.OTGW_BUILD: [None, None, "Gateway Firmware Build"],
|
||||
gw_vars.OTGW_CLOCKMHZ: [None, None, "Gateway Clock Speed"],
|
||||
gw_vars.OTGW_LED_A: [None, None, "Gateway LED A Mode"],
|
||||
gw_vars.OTGW_LED_B: [None, None, "Gateway LED B Mode"],
|
||||
gw_vars.OTGW_LED_C: [None, None, "Gateway LED C Mode"],
|
||||
gw_vars.OTGW_LED_D: [None, None, "Gateway LED D Mode"],
|
||||
gw_vars.OTGW_LED_E: [None, None, "Gateway LED E Mode"],
|
||||
gw_vars.OTGW_LED_F: [None, None, "Gateway LED F Mode"],
|
||||
gw_vars.OTGW_GPIO_A: [None, None, "Gateway GPIO A Mode"],
|
||||
gw_vars.OTGW_GPIO_B: [None, None, "Gateway GPIO B Mode"],
|
||||
gw_vars.OTGW_SB_TEMP: [
|
||||
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
|
||||
"Gateway Setback Temperature"],
|
||||
gw_vars.OTGW_SETP_OVRD_MODE: [
|
||||
None, None, "Gateway Room Setpoint Override Mode"],
|
||||
gw_vars.OTGW_SMART_PWR: [None, None, "Gateway Smart Power Mode"],
|
||||
gw_vars.OTGW_THRM_DETECT: [None, None, "Gateway Thermostat Detection"],
|
||||
gw_vars.OTGW_VREF: [None, None, "Gateway Reference Voltage Setting"],
|
||||
}
|
||||
sensors = []
|
||||
for var in discovery_info:
|
||||
device_class = sensor_info[var][0]
|
||||
unit = sensor_info[var][1]
|
||||
friendly_name = sensor_info[var][2]
|
||||
entity_id = async_generate_entity_id(ENTITY_ID_FORMAT, var, hass=hass)
|
||||
sensors.append(
|
||||
OpenThermSensor(entity_id, var, device_class, unit, friendly_name))
|
||||
async_add_entities(sensors)
|
||||
|
||||
|
||||
class OpenThermSensor(Entity):
|
||||
"""Representation of an OpenTherm Gateway sensor."""
|
||||
|
||||
def __init__(self, entity_id, var, device_class, unit, friendly_name):
|
||||
"""Initialize the sensor."""
|
||||
self.entity_id = entity_id
|
||||
self._var = var
|
||||
self._value = None
|
||||
self._device_class = device_class
|
||||
self._unit = unit
|
||||
self._friendly_name = friendly_name
|
||||
|
||||
async def async_added_to_hass(self):
|
||||
"""Subscribe to updates from the component."""
|
||||
_LOGGER.debug("Added OpenTherm Gateway sensor %s", self._friendly_name)
|
||||
async_dispatcher_connect(self.hass, SIGNAL_OPENTHERM_GW_UPDATE,
|
||||
self.receive_report)
|
||||
|
||||
async def receive_report(self, status):
|
||||
"""Handle status updates from the component."""
|
||||
value = status.get(self._var)
|
||||
if isinstance(value, float):
|
||||
value = '{:2.1f}'.format(value)
|
||||
self._value = value
|
||||
self.async_schedule_update_ha_state()
|
||||
|
||||
@property
|
||||
def name(self):
|
||||
"""Return the friendly name of the sensor."""
|
||||
return self._friendly_name
|
||||
|
||||
@property
|
||||
def device_class(self):
|
||||
"""Return the device class."""
|
||||
return self._device_class
|
||||
|
||||
@property
|
||||
def state(self):
|
||||
"""Return the state of the device."""
|
||||
return self._value
|
||||
|
||||
@property
|
||||
def unit_of_measurement(self):
|
||||
"""Return the unit of measurement."""
|
||||
return self._unit
|
||||
|
||||
@property
|
||||
def should_poll(self):
|
||||
"""Return False because entity pushes its state."""
|
||||
return False
|
|
@ -1033,7 +1033,7 @@ pyoppleio==1.0.5
|
|||
pyota==2.0.5
|
||||
|
||||
# homeassistant.components.opentherm_gw
|
||||
pyotgw==0.1b0
|
||||
pyotgw==0.2b1
|
||||
|
||||
# homeassistant.auth.mfa_modules.notify
|
||||
# homeassistant.auth.mfa_modules.totp
|
||||
|
|
Loading…
Add table
Reference in a new issue