Add sensor support to opentherm_gw ()

* Add OpenTherm Gateway sensor platform.

* Add OTGW_ variables to list of supported sensors.

* Order imports.

* Add OpenTherm Gateway binary sensor support.

* Revert "Add OpenTherm Gateway binary sensor support."

This reverts commit 115acaa912.

* Import COMP_SENSOR from sensor component rather than defining it.

* Update opentherm_gw sensor platform docs url.

* Update dependency to v0.2b1
Old version had incorrect variable names for some of the sensors

* Update requirements_all.txt

* Address review findings.

* Update .coveragerc
This commit is contained in:
mvn23 2018-10-19 07:31:19 +02:00 committed by Martin Hjelmare
parent cc4d29d42a
commit 7baffed7b7
4 changed files with 304 additions and 5 deletions

View file

@ -249,7 +249,7 @@ omit =
homeassistant/components/*/opencv.py
homeassistant/components/opentherm_gw.py
homeassistant/components/climate/opentherm_gw.py
homeassistant/components/*/opentherm_gw.py
homeassistant/components/openuv/__init__.py
homeassistant/components/*/openuv.py

View file

@ -8,8 +8,10 @@ import logging
import voluptuous as vol
from homeassistant.const import (CONF_DEVICE, CONF_NAME, PRECISION_HALVES,
PRECISION_TENTHS, PRECISION_WHOLE)
from homeassistant.components.sensor import DOMAIN as COMP_SENSOR
from homeassistant.const import (CONF_DEVICE, CONF_MONITORED_VARIABLES,
CONF_NAME, PRECISION_HALVES, PRECISION_TENTHS,
PRECISION_WHOLE)
from homeassistant.helpers.discovery import async_load_platform
from homeassistant.helpers.dispatcher import async_dispatcher_send
@ -38,10 +40,12 @@ CONFIG_SCHEMA = vol.Schema({
DOMAIN: vol.Schema({
vol.Required(CONF_DEVICE): cv.string,
vol.Optional(CONF_CLIMATE, default={}): CLIMATE_SCHEMA,
vol.Optional(CONF_MONITORED_VARIABLES, default=[]): vol.All(
cv.ensure_list, [cv.string]),
}),
}, extra=vol.ALLOW_EXTRA)
REQUIREMENTS = ['pyotgw==0.1b0']
REQUIREMENTS = ['pyotgw==0.2b1']
_LOGGER = logging.getLogger(__name__)
@ -59,6 +63,8 @@ async def async_setup(hass, config):
hass, conf[CONF_DEVICE], gateway))
hass.async_create_task(async_load_platform(
hass, 'climate', DOMAIN, conf.get(CONF_CLIMATE)))
hass.async_create_task(setup_monitored_vars(
hass, conf.get(CONF_MONITORED_VARIABLES)))
return True
@ -72,3 +78,85 @@ async def connect_and_subscribe(hass, device_path, gateway):
_LOGGER.debug("Received report: %s", status)
async_dispatcher_send(hass, SIGNAL_OPENTHERM_GW_UPDATE, status)
gateway.subscribe(handle_report)
async def setup_monitored_vars(hass, monitored_vars):
"""Set up requested sensors."""
gw_vars = hass.data[DATA_OPENTHERM_GW][DATA_GW_VARS]
# Use dict to prepare for binary sensor support.
sensor_type_map = {
COMP_SENSOR: [
gw_vars.DATA_CONTROL_SETPOINT,
gw_vars.DATA_MASTER_MEMBERID,
gw_vars.DATA_SLAVE_MEMBERID,
gw_vars.DATA_SLAVE_OEM_FAULT,
gw_vars.DATA_COOLING_CONTROL,
gw_vars.DATA_CONTROL_SETPOINT_2,
gw_vars.DATA_ROOM_SETPOINT_OVRD,
gw_vars.DATA_SLAVE_MAX_RELATIVE_MOD,
gw_vars.DATA_SLAVE_MAX_CAPACITY,
gw_vars.DATA_SLAVE_MIN_MOD_LEVEL,
gw_vars.DATA_ROOM_SETPOINT,
gw_vars.DATA_REL_MOD_LEVEL,
gw_vars.DATA_CH_WATER_PRESS,
gw_vars.DATA_DHW_FLOW_RATE,
gw_vars.DATA_ROOM_SETPOINT_2,
gw_vars.DATA_ROOM_TEMP,
gw_vars.DATA_CH_WATER_TEMP,
gw_vars.DATA_DHW_TEMP,
gw_vars.DATA_OUTSIDE_TEMP,
gw_vars.DATA_RETURN_WATER_TEMP,
gw_vars.DATA_SOLAR_STORAGE_TEMP,
gw_vars.DATA_SOLAR_COLL_TEMP,
gw_vars.DATA_CH_WATER_TEMP_2,
gw_vars.DATA_DHW_TEMP_2,
gw_vars.DATA_EXHAUST_TEMP,
gw_vars.DATA_SLAVE_DHW_MAX_SETP,
gw_vars.DATA_SLAVE_DHW_MIN_SETP,
gw_vars.DATA_SLAVE_CH_MAX_SETP,
gw_vars.DATA_SLAVE_CH_MIN_SETP,
gw_vars.DATA_DHW_SETPOINT,
gw_vars.DATA_MAX_CH_SETPOINT,
gw_vars.DATA_OEM_DIAG,
gw_vars.DATA_TOTAL_BURNER_STARTS,
gw_vars.DATA_CH_PUMP_STARTS,
gw_vars.DATA_DHW_PUMP_STARTS,
gw_vars.DATA_DHW_BURNER_STARTS,
gw_vars.DATA_TOTAL_BURNER_HOURS,
gw_vars.DATA_CH_PUMP_HOURS,
gw_vars.DATA_DHW_PUMP_HOURS,
gw_vars.DATA_DHW_BURNER_HOURS,
gw_vars.DATA_MASTER_OT_VERSION,
gw_vars.DATA_SLAVE_OT_VERSION,
gw_vars.DATA_MASTER_PRODUCT_TYPE,
gw_vars.DATA_MASTER_PRODUCT_VERSION,
gw_vars.DATA_SLAVE_PRODUCT_TYPE,
gw_vars.DATA_SLAVE_PRODUCT_VERSION,
gw_vars.OTGW_MODE,
gw_vars.OTGW_DHW_OVRD,
gw_vars.OTGW_ABOUT,
gw_vars.OTGW_BUILD,
gw_vars.OTGW_CLOCKMHZ,
gw_vars.OTGW_LED_A,
gw_vars.OTGW_LED_B,
gw_vars.OTGW_LED_C,
gw_vars.OTGW_LED_D,
gw_vars.OTGW_LED_E,
gw_vars.OTGW_LED_F,
gw_vars.OTGW_GPIO_A,
gw_vars.OTGW_GPIO_B,
gw_vars.OTGW_SB_TEMP,
gw_vars.OTGW_SETP_OVRD_MODE,
gw_vars.OTGW_SMART_PWR,
gw_vars.OTGW_THRM_DETECT,
gw_vars.OTGW_VREF,
]
}
sensors = []
for var in monitored_vars:
if var in sensor_type_map[COMP_SENSOR]:
sensors.append(var)
else:
_LOGGER.error("Monitored variable not supported: %s", var)
if sensors:
await async_load_platform(hass, COMP_SENSOR, DOMAIN, sensors)

View file

@ -0,0 +1,211 @@
"""
Support for OpenTherm Gateway sensors.
For more details about this platform, please refer to the documentation at
http://home-assistant.io/components/sensor.opentherm_gw/
"""
import logging
from homeassistant.components.opentherm_gw import (
DATA_GW_VARS, DATA_OPENTHERM_GW, SIGNAL_OPENTHERM_GW_UPDATE)
from homeassistant.components.sensor import ENTITY_ID_FORMAT
from homeassistant.const import DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS
from homeassistant.helpers.dispatcher import async_dispatcher_connect
from homeassistant.helpers.entity import Entity, async_generate_entity_id
UNIT_BAR = 'bar'
UNIT_HOUR = 'h'
UNIT_KW = 'kW'
UNIT_L_MIN = 'L/min'
UNIT_PERCENT = '%'
DEPENDENCIES = ['opentherm_gw']
_LOGGER = logging.getLogger(__name__)
async def async_setup_platform(hass, config, async_add_entities,
discovery_info=None):
"""Set up the OpenTherm Gateway sensors."""
if discovery_info is None:
return
gw_vars = hass.data[DATA_OPENTHERM_GW][DATA_GW_VARS]
sensor_info = {
# [device_class, unit, friendly_name]
gw_vars.DATA_CONTROL_SETPOINT: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Control Setpoint"],
gw_vars.DATA_MASTER_MEMBERID: [None, None, "Thermostat Member ID"],
gw_vars.DATA_SLAVE_MEMBERID: [None, None, "Boiler Member ID"],
gw_vars.DATA_SLAVE_OEM_FAULT: [None, None, "Boiler OEM Fault Code"],
gw_vars.DATA_COOLING_CONTROL: [
None, UNIT_PERCENT, "Cooling Control Signal"],
gw_vars.DATA_CONTROL_SETPOINT_2: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Control Setpoint 2"],
gw_vars.DATA_ROOM_SETPOINT_OVRD: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Room Setpoint Override"],
gw_vars.DATA_SLAVE_MAX_RELATIVE_MOD: [
None, UNIT_PERCENT, "Boiler Maximum Relative Modulation"],
gw_vars.DATA_SLAVE_MAX_CAPACITY: [
None, UNIT_KW, "Boiler Maximum Capacity"],
gw_vars.DATA_SLAVE_MIN_MOD_LEVEL: [
None, UNIT_PERCENT, "Boiler Minimum Modulation Level"],
gw_vars.DATA_ROOM_SETPOINT: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Room Setpoint"],
gw_vars.DATA_REL_MOD_LEVEL: [
None, UNIT_PERCENT, "Relative Modulation Level"],
gw_vars.DATA_CH_WATER_PRESS: [
None, UNIT_BAR, "Central Heating Water Pressure"],
gw_vars.DATA_DHW_FLOW_RATE: [None, UNIT_L_MIN, "Hot Water Flow Rate"],
gw_vars.DATA_ROOM_SETPOINT_2: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Room Setpoint 2"],
gw_vars.DATA_ROOM_TEMP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Room Temperature"],
gw_vars.DATA_CH_WATER_TEMP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Central Heating Water Temperature"],
gw_vars.DATA_DHW_TEMP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Hot Water Temperature"],
gw_vars.DATA_OUTSIDE_TEMP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Outside Temperature"],
gw_vars.DATA_RETURN_WATER_TEMP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Return Water Temperature"],
gw_vars.DATA_SOLAR_STORAGE_TEMP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Solar Storage Temperature"],
gw_vars.DATA_SOLAR_COLL_TEMP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Solar Collector Temperature"],
gw_vars.DATA_CH_WATER_TEMP_2: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Central Heating 2 Water Temperature"],
gw_vars.DATA_DHW_TEMP_2: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Hot Water 2 Temperature"],
gw_vars.DATA_EXHAUST_TEMP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Exhaust Temperature"],
gw_vars.DATA_SLAVE_DHW_MAX_SETP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Hot Water Maximum Setpoint"],
gw_vars.DATA_SLAVE_DHW_MIN_SETP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Hot Water Minimum Setpoint"],
gw_vars.DATA_SLAVE_CH_MAX_SETP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Boiler Maximum Central Heating Setpoint"],
gw_vars.DATA_SLAVE_CH_MIN_SETP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Boiler Minimum Central Heating Setpoint"],
gw_vars.DATA_DHW_SETPOINT: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS, "Hot Water Setpoint"],
gw_vars.DATA_MAX_CH_SETPOINT: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Maximum Central Heating Setpoint"],
gw_vars.DATA_OEM_DIAG: [None, None, "OEM Diagnostic Code"],
gw_vars.DATA_TOTAL_BURNER_STARTS: [
None, None, "Total Burner Starts"],
gw_vars.DATA_CH_PUMP_STARTS: [
None, None, "Central Heating Pump Starts"],
gw_vars.DATA_DHW_PUMP_STARTS: [None, None, "Hot Water Pump Starts"],
gw_vars.DATA_DHW_BURNER_STARTS: [
None, None, "Hot Water Burner Starts"],
gw_vars.DATA_TOTAL_BURNER_HOURS: [
None, UNIT_HOUR, "Total Burner Hours"],
gw_vars.DATA_CH_PUMP_HOURS: [
None, UNIT_HOUR, "Central Heating Pump Hours"],
gw_vars.DATA_DHW_PUMP_HOURS: [None, UNIT_HOUR, "Hot Water Pump Hours"],
gw_vars.DATA_DHW_BURNER_HOURS: [
None, UNIT_HOUR, "Hot Water Burner Hours"],
gw_vars.DATA_MASTER_OT_VERSION: [
None, None, "Thermostat OpenTherm Version"],
gw_vars.DATA_SLAVE_OT_VERSION: [
None, None, "Boiler OpenTherm Version"],
gw_vars.DATA_MASTER_PRODUCT_TYPE: [
None, None, "Thermostat Product Type"],
gw_vars.DATA_MASTER_PRODUCT_VERSION: [
None, None, "Thermostat Product Version"],
gw_vars.DATA_SLAVE_PRODUCT_TYPE: [None, None, "Boiler Product Type"],
gw_vars.DATA_SLAVE_PRODUCT_VERSION: [
None, None, "Boiler Product Version"],
gw_vars.OTGW_MODE: [None, None, "Gateway/Monitor Mode"],
gw_vars.OTGW_DHW_OVRD: [None, None, "Gateway Hot Water Override Mode"],
gw_vars.OTGW_ABOUT: [None, None, "Gateway Firmware Version"],
gw_vars.OTGW_BUILD: [None, None, "Gateway Firmware Build"],
gw_vars.OTGW_CLOCKMHZ: [None, None, "Gateway Clock Speed"],
gw_vars.OTGW_LED_A: [None, None, "Gateway LED A Mode"],
gw_vars.OTGW_LED_B: [None, None, "Gateway LED B Mode"],
gw_vars.OTGW_LED_C: [None, None, "Gateway LED C Mode"],
gw_vars.OTGW_LED_D: [None, None, "Gateway LED D Mode"],
gw_vars.OTGW_LED_E: [None, None, "Gateway LED E Mode"],
gw_vars.OTGW_LED_F: [None, None, "Gateway LED F Mode"],
gw_vars.OTGW_GPIO_A: [None, None, "Gateway GPIO A Mode"],
gw_vars.OTGW_GPIO_B: [None, None, "Gateway GPIO B Mode"],
gw_vars.OTGW_SB_TEMP: [
DEVICE_CLASS_TEMPERATURE, TEMP_CELSIUS,
"Gateway Setback Temperature"],
gw_vars.OTGW_SETP_OVRD_MODE: [
None, None, "Gateway Room Setpoint Override Mode"],
gw_vars.OTGW_SMART_PWR: [None, None, "Gateway Smart Power Mode"],
gw_vars.OTGW_THRM_DETECT: [None, None, "Gateway Thermostat Detection"],
gw_vars.OTGW_VREF: [None, None, "Gateway Reference Voltage Setting"],
}
sensors = []
for var in discovery_info:
device_class = sensor_info[var][0]
unit = sensor_info[var][1]
friendly_name = sensor_info[var][2]
entity_id = async_generate_entity_id(ENTITY_ID_FORMAT, var, hass=hass)
sensors.append(
OpenThermSensor(entity_id, var, device_class, unit, friendly_name))
async_add_entities(sensors)
class OpenThermSensor(Entity):
"""Representation of an OpenTherm Gateway sensor."""
def __init__(self, entity_id, var, device_class, unit, friendly_name):
"""Initialize the sensor."""
self.entity_id = entity_id
self._var = var
self._value = None
self._device_class = device_class
self._unit = unit
self._friendly_name = friendly_name
async def async_added_to_hass(self):
"""Subscribe to updates from the component."""
_LOGGER.debug("Added OpenTherm Gateway sensor %s", self._friendly_name)
async_dispatcher_connect(self.hass, SIGNAL_OPENTHERM_GW_UPDATE,
self.receive_report)
async def receive_report(self, status):
"""Handle status updates from the component."""
value = status.get(self._var)
if isinstance(value, float):
value = '{:2.1f}'.format(value)
self._value = value
self.async_schedule_update_ha_state()
@property
def name(self):
"""Return the friendly name of the sensor."""
return self._friendly_name
@property
def device_class(self):
"""Return the device class."""
return self._device_class
@property
def state(self):
"""Return the state of the device."""
return self._value
@property
def unit_of_measurement(self):
"""Return the unit of measurement."""
return self._unit
@property
def should_poll(self):
"""Return False because entity pushes its state."""
return False

View file

@ -1033,7 +1033,7 @@ pyoppleio==1.0.5
pyota==2.0.5
# homeassistant.components.opentherm_gw
pyotgw==0.1b0
pyotgw==0.2b1
# homeassistant.auth.mfa_modules.notify
# homeassistant.auth.mfa_modules.totp