Fix temperature stepping in Sensibo (#67737)
Co-authored-by: Paulus Schoutsen <paulus@home-assistant.io>
This commit is contained in:
parent
48e6738367
commit
7041bc797a
1 changed files with 7 additions and 1 deletions
|
@ -17,6 +17,8 @@ from homeassistant.helpers.update_coordinator import DataUpdateCoordinator, Upda
|
|||
|
||||
from .const import DEFAULT_SCAN_INTERVAL, DOMAIN, LOGGER, TIMEOUT
|
||||
|
||||
MAX_POSSIBLE_STEP = 1000
|
||||
|
||||
|
||||
@dataclass
|
||||
class MotionSensor:
|
||||
|
@ -93,7 +95,11 @@ class SensiboDataUpdateCoordinator(DataUpdateCoordinator):
|
|||
.get("values", [0, 1])
|
||||
)
|
||||
if temperatures_list:
|
||||
temperature_step = temperatures_list[1] - temperatures_list[0]
|
||||
diff = MAX_POSSIBLE_STEP
|
||||
for i in range(len(temperatures_list) - 1):
|
||||
if temperatures_list[i + 1] - temperatures_list[i] < diff:
|
||||
diff = temperatures_list[i + 1] - temperatures_list[i]
|
||||
temperature_step = diff
|
||||
|
||||
active_features = list(ac_states)
|
||||
full_features = set()
|
||||
|
|