Correct number of registers to read for sensors for modbus (#98534)
This commit is contained in:
parent
2f204d5747
commit
5a7084e78c
1 changed files with 1 additions and 1 deletions
|
@ -68,7 +68,7 @@ class ModbusRegisterSensor(BaseStructPlatform, RestoreSensor, SensorEntity):
|
|||
"""Initialize the modbus register sensor."""
|
||||
super().__init__(hub, entry)
|
||||
if slave_count:
|
||||
self._count = self._count * slave_count
|
||||
self._count = self._count * (slave_count + 1)
|
||||
self._coordinator: DataUpdateCoordinator[list[int] | None] | None = None
|
||||
self._attr_native_unit_of_measurement = entry.get(CONF_UNIT_OF_MEASUREMENT)
|
||||
self._attr_state_class = entry.get(CONF_STATE_CLASS)
|
||||
|
|