From 45a41421b6797b88e92dc525a2ddf85e1427636a Mon Sep 17 00:00:00 2001 From: Osma Ahvenlampi Date: Thu, 12 Jan 2023 11:29:54 +0200 Subject: [PATCH] Change Ruuvi movement counter to correct state class (#85677) change Ruuvi movement counter to correct class The counter's values are 0 to 255 increasing value, so the correct state class as per https://developers.home-assistant.io/docs/core/entity/sensor/#entities-representing-a-total-amount is TOTAL_INCREASING. --- homeassistant/components/ruuvitag_ble/sensor.py | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/homeassistant/components/ruuvitag_ble/sensor.py b/homeassistant/components/ruuvitag_ble/sensor.py index bd21e479abf..ebdf2c5f264 100644 --- a/homeassistant/components/ruuvitag_ble/sensor.py +++ b/homeassistant/components/ruuvitag_ble/sensor.py @@ -77,7 +77,7 @@ SENSOR_DESCRIPTIONS = { ), (SSDSensorDeviceClass.COUNT, None): SensorEntityDescription( key="movement_counter", - state_class=SensorStateClass.MEASUREMENT, + state_class=SensorStateClass.TOTAL_INCREASING, entity_registry_enabled_default=False, ), }