Don't poll ZHA electrical measurement sensors unnecessarily (#92330)
This commit is contained in:
parent
adaae46178
commit
2bc2c4a651
3 changed files with 32 additions and 18 deletions
|
@ -248,13 +248,16 @@ class Battery(Sensor):
|
|||
return state_attrs
|
||||
|
||||
|
||||
@MULTI_MATCH(cluster_handler_names=CLUSTER_HANDLER_ELECTRICAL_MEASUREMENT)
|
||||
@MULTI_MATCH(
|
||||
cluster_handler_names=CLUSTER_HANDLER_ELECTRICAL_MEASUREMENT,
|
||||
stop_on_match_group=CLUSTER_HANDLER_ELECTRICAL_MEASUREMENT,
|
||||
models={"VZM31-SN", "SP 234", "outletv4"},
|
||||
)
|
||||
class ElectricalMeasurement(Sensor):
|
||||
"""Active power measurement."""
|
||||
|
||||
SENSOR_ATTR = "active_power"
|
||||
_attr_device_class: SensorDeviceClass = SensorDeviceClass.POWER
|
||||
_attr_should_poll = True # BaseZhaEntity defaults to False
|
||||
_attr_state_class: SensorStateClass = SensorStateClass.MEASUREMENT
|
||||
_attr_name: str = "Active power"
|
||||
_attr_native_unit_of_measurement: str = UnitOfPower.WATT
|
||||
|
@ -284,6 +287,16 @@ class ElectricalMeasurement(Sensor):
|
|||
return round(value, self._decimals)
|
||||
return round(value)
|
||||
|
||||
|
||||
@MULTI_MATCH(
|
||||
cluster_handler_names=CLUSTER_HANDLER_ELECTRICAL_MEASUREMENT,
|
||||
stop_on_match_group=CLUSTER_HANDLER_ELECTRICAL_MEASUREMENT,
|
||||
)
|
||||
class PolledElectricalMeasurement(ElectricalMeasurement):
|
||||
"""Polled active power measurement."""
|
||||
|
||||
_attr_should_poll = True # BaseZhaEntity defaults to False
|
||||
|
||||
async def async_update(self) -> None:
|
||||
"""Retrieve latest state."""
|
||||
if not self.available:
|
||||
|
@ -299,7 +312,6 @@ class ElectricalMeasurementApparentPower(
|
|||
|
||||
SENSOR_ATTR = "apparent_power"
|
||||
_attr_device_class: SensorDeviceClass = SensorDeviceClass.APPARENT_POWER
|
||||
_attr_should_poll = False # Poll indirectly by ElectricalMeasurementSensor
|
||||
_attr_name: str = "Apparent power"
|
||||
_attr_native_unit_of_measurement = UnitOfApparentPower.VOLT_AMPERE
|
||||
_div_mul_prefix = "ac_power"
|
||||
|
@ -311,7 +323,6 @@ class ElectricalMeasurementRMSCurrent(ElectricalMeasurement, id_suffix="rms_curr
|
|||
|
||||
SENSOR_ATTR = "rms_current"
|
||||
_attr_device_class: SensorDeviceClass = SensorDeviceClass.CURRENT
|
||||
_attr_should_poll = False # Poll indirectly by ElectricalMeasurementSensor
|
||||
_attr_name: str = "RMS current"
|
||||
_attr_native_unit_of_measurement = UnitOfElectricCurrent.AMPERE
|
||||
_div_mul_prefix = "ac_current"
|
||||
|
@ -323,7 +334,6 @@ class ElectricalMeasurementRMSVoltage(ElectricalMeasurement, id_suffix="rms_volt
|
|||
|
||||
SENSOR_ATTR = "rms_voltage"
|
||||
_attr_device_class: SensorDeviceClass = SensorDeviceClass.VOLTAGE
|
||||
_attr_should_poll = False # Poll indirectly by ElectricalMeasurementSensor
|
||||
_attr_name: str = "RMS voltage"
|
||||
_attr_native_unit_of_measurement = UnitOfElectricPotential.VOLT
|
||||
_div_mul_prefix = "ac_voltage"
|
||||
|
@ -335,7 +345,6 @@ class ElectricalMeasurementFrequency(ElectricalMeasurement, id_suffix="ac_freque
|
|||
|
||||
SENSOR_ATTR = "ac_frequency"
|
||||
_attr_device_class: SensorDeviceClass = SensorDeviceClass.FREQUENCY
|
||||
_attr_should_poll = False # Poll indirectly by ElectricalMeasurementSensor
|
||||
_attr_name: str = "AC frequency"
|
||||
_attr_native_unit_of_measurement = UnitOfFrequency.HERTZ
|
||||
_div_mul_prefix = "ac_frequency"
|
||||
|
@ -347,7 +356,6 @@ class ElectricalMeasurementPowerFactor(ElectricalMeasurement, id_suffix="power_f
|
|||
|
||||
SENSOR_ATTR = "power_factor"
|
||||
_attr_device_class: SensorDeviceClass = SensorDeviceClass.POWER_FACTOR
|
||||
_attr_should_poll = False # Poll indirectly by ElectricalMeasurementSensor
|
||||
_attr_name: str = "Power factor"
|
||||
_attr_native_unit_of_measurement = PERCENTAGE
|
||||
|
||||
|
|