Bugfix default values to timedelta (#5193)

* Bugfix default values to timedelta

* fix unittests
This commit is contained in:
Pascal Vizeli 2017-01-06 00:16:12 +01:00 committed by GitHub
parent c959637ebe
commit 1719d88602
20 changed files with 44 additions and 36 deletions

View file

@ -5,6 +5,7 @@ For more details about this component, please refer to the documentation at
https://home-assistant.io/components/binary_sensor/
"""
import asyncio
from datetime import timedelta
import logging
import voluptuous as vol
@ -15,7 +16,7 @@ from homeassistant.const import (STATE_ON, STATE_OFF)
from homeassistant.helpers.config_validation import PLATFORM_SCHEMA # noqa
DOMAIN = 'binary_sensor'
SCAN_INTERVAL = 30
SCAN_INTERVAL = timedelta(seconds=30)
ENTITY_ID_FORMAT = DOMAIN + '.{}'
SENSOR_CLASSES = [

View file

@ -4,6 +4,7 @@ Support for custom shell commands to retrieve values.
For more details about this platform, please refer to the documentation at
https://home-assistant.io/components/binary_sensor.command_line/
"""
from datetime import timedelta
import logging
import voluptuous as vol
@ -22,7 +23,7 @@ DEFAULT_NAME = 'Binary Command Sensor'
DEFAULT_PAYLOAD_ON = 'ON'
DEFAULT_PAYLOAD_OFF = 'OFF'
SCAN_INTERVAL = 60
SCAN_INTERVAL = timedelta(seconds=60)
PLATFORM_SCHEMA = PLATFORM_SCHEMA.extend({
vol.Required(CONF_COMMAND): cv.string,

View file

@ -27,7 +27,7 @@ DEFAULT_NAME = 'Alarm'
DEFAULT_PORT = '5007'
DEFAULT_SSL = False
SCAN_INTERVAL = 1
SCAN_INTERVAL = datetime.timedelta(seconds=1)
ZONE_TYPES_SCHEMA = vol.Schema({
cv.positive_int: vol.In(SENSOR_CLASSES),