Fix Lyric LCC thermostats auto mode (#104853)
This commit is contained in:
parent
47dc48ca66
commit
0fa3ce763e
1 changed files with 66 additions and 43 deletions
|
@ -2,6 +2,7 @@
|
|||
from __future__ import annotations
|
||||
|
||||
import asyncio
|
||||
import enum
|
||||
import logging
|
||||
from time import localtime, strftime, time
|
||||
from typing import Any
|
||||
|
@ -151,6 +152,13 @@ async def async_setup_entry(
|
|||
)
|
||||
|
||||
|
||||
class LyricThermostatType(enum.Enum):
|
||||
"""Lyric thermostats are classified as TCC or LCC devices."""
|
||||
|
||||
TCC = enum.auto()
|
||||
LCC = enum.auto()
|
||||
|
||||
|
||||
class LyricClimate(LyricDeviceEntity, ClimateEntity):
|
||||
"""Defines a Honeywell Lyric climate entity."""
|
||||
|
||||
|
@ -201,8 +209,10 @@ class LyricClimate(LyricDeviceEntity, ClimateEntity):
|
|||
# Setup supported features
|
||||
if device.changeableValues.thermostatSetpointStatus:
|
||||
self._attr_supported_features = SUPPORT_FLAGS_LCC
|
||||
self._attr_thermostat_type = LyricThermostatType.LCC
|
||||
else:
|
||||
self._attr_supported_features = SUPPORT_FLAGS_TCC
|
||||
self._attr_thermostat_type = LyricThermostatType.TCC
|
||||
|
||||
# Setup supported fan modes
|
||||
if device_fan_modes := device.settings.attributes.get("fan", {}).get(
|
||||
|
@ -365,56 +375,69 @@ class LyricClimate(LyricDeviceEntity, ClimateEntity):
|
|||
"""Set hvac mode."""
|
||||
_LOGGER.debug("HVAC mode: %s", hvac_mode)
|
||||
try:
|
||||
if LYRIC_HVAC_MODES[hvac_mode] == LYRIC_HVAC_MODE_HEAT_COOL:
|
||||
# If the system is off, turn it to Heat first then to Auto,
|
||||
# otherwise it turns to.
|
||||
# Auto briefly and then reverts to Off (perhaps related to
|
||||
# heatCoolMode). This is the behavior that happens with the
|
||||
# native app as well, so likely a bug in the api itself
|
||||
if HVAC_MODES[self.device.changeableValues.mode] == HVACMode.OFF:
|
||||
_LOGGER.debug(
|
||||
"HVAC mode passed to lyric: %s",
|
||||
HVAC_MODES[LYRIC_HVAC_MODE_COOL],
|
||||
)
|
||||
await self._update_thermostat(
|
||||
self.location,
|
||||
self.device,
|
||||
mode=HVAC_MODES[LYRIC_HVAC_MODE_HEAT],
|
||||
autoChangeoverActive=False,
|
||||
)
|
||||
# Sleep 3 seconds before proceeding
|
||||
await asyncio.sleep(3)
|
||||
_LOGGER.debug(
|
||||
"HVAC mode passed to lyric: %s",
|
||||
HVAC_MODES[LYRIC_HVAC_MODE_HEAT],
|
||||
)
|
||||
await self._update_thermostat(
|
||||
self.location,
|
||||
self.device,
|
||||
mode=HVAC_MODES[LYRIC_HVAC_MODE_HEAT],
|
||||
autoChangeoverActive=True,
|
||||
)
|
||||
else:
|
||||
_LOGGER.debug(
|
||||
"HVAC mode passed to lyric: %s",
|
||||
HVAC_MODES[self.device.changeableValues.mode],
|
||||
)
|
||||
await self._update_thermostat(
|
||||
self.location, self.device, autoChangeoverActive=True
|
||||
)
|
||||
else:
|
||||
match self._attr_thermostat_type:
|
||||
case LyricThermostatType.TCC:
|
||||
await self._async_set_hvac_mode_tcc(hvac_mode)
|
||||
case LyricThermostatType.LCC:
|
||||
await self._async_set_hvac_mode_lcc(hvac_mode)
|
||||
except LYRIC_EXCEPTIONS as exception:
|
||||
_LOGGER.error(exception)
|
||||
await self.coordinator.async_refresh()
|
||||
|
||||
async def _async_set_hvac_mode_tcc(self, hvac_mode: HVACMode) -> None:
|
||||
if LYRIC_HVAC_MODES[hvac_mode] == LYRIC_HVAC_MODE_HEAT_COOL:
|
||||
# If the system is off, turn it to Heat first then to Auto,
|
||||
# otherwise it turns to.
|
||||
# Auto briefly and then reverts to Off (perhaps related to
|
||||
# heatCoolMode). This is the behavior that happens with the
|
||||
# native app as well, so likely a bug in the api itself
|
||||
if HVAC_MODES[self.device.changeableValues.mode] == HVACMode.OFF:
|
||||
_LOGGER.debug(
|
||||
"HVAC mode passed to lyric: %s", LYRIC_HVAC_MODES[hvac_mode]
|
||||
"HVAC mode passed to lyric: %s",
|
||||
HVAC_MODES[LYRIC_HVAC_MODE_COOL],
|
||||
)
|
||||
await self._update_thermostat(
|
||||
self.location,
|
||||
self.device,
|
||||
mode=LYRIC_HVAC_MODES[hvac_mode],
|
||||
mode=HVAC_MODES[LYRIC_HVAC_MODE_HEAT],
|
||||
autoChangeoverActive=False,
|
||||
)
|
||||
except LYRIC_EXCEPTIONS as exception:
|
||||
_LOGGER.error(exception)
|
||||
await self.coordinator.async_refresh()
|
||||
# Sleep 3 seconds before proceeding
|
||||
await asyncio.sleep(3)
|
||||
_LOGGER.debug(
|
||||
"HVAC mode passed to lyric: %s",
|
||||
HVAC_MODES[LYRIC_HVAC_MODE_HEAT],
|
||||
)
|
||||
await self._update_thermostat(
|
||||
self.location,
|
||||
self.device,
|
||||
mode=HVAC_MODES[LYRIC_HVAC_MODE_HEAT],
|
||||
autoChangeoverActive=True,
|
||||
)
|
||||
else:
|
||||
_LOGGER.debug(
|
||||
"HVAC mode passed to lyric: %s",
|
||||
HVAC_MODES[self.device.changeableValues.mode],
|
||||
)
|
||||
await self._update_thermostat(
|
||||
self.location, self.device, autoChangeoverActive=True
|
||||
)
|
||||
else:
|
||||
_LOGGER.debug("HVAC mode passed to lyric: %s", LYRIC_HVAC_MODES[hvac_mode])
|
||||
await self._update_thermostat(
|
||||
self.location,
|
||||
self.device,
|
||||
mode=LYRIC_HVAC_MODES[hvac_mode],
|
||||
autoChangeoverActive=False,
|
||||
)
|
||||
|
||||
async def _async_set_hvac_mode_lcc(self, hvac_mode: HVACMode) -> None:
|
||||
_LOGGER.debug("HVAC mode passed to lyric: %s", LYRIC_HVAC_MODES[hvac_mode])
|
||||
await self._update_thermostat(
|
||||
self.location,
|
||||
self.device,
|
||||
mode=LYRIC_HVAC_MODES[hvac_mode],
|
||||
)
|
||||
|
||||
async def async_set_preset_mode(self, preset_mode: str) -> None:
|
||||
"""Set preset (PermanentHold, HoldUntil, NoHold, VacationHold) mode."""
|
||||
|
|
Loading…