Update HomeKit VOC mappings (#87663)
Co-authored-by: J. Nick Koston <nick@koston.org>
This commit is contained in:
parent
9c82cfecca
commit
0b81c836ef
3 changed files with 38 additions and 20 deletions
|
@ -447,16 +447,21 @@ def density_to_air_quality_nitrogen_dioxide(density: float) -> int:
|
|||
|
||||
|
||||
def density_to_air_quality_voc(density: float) -> int:
|
||||
"""Map VOCs µg/m3 to HomeKit AirQuality level."""
|
||||
if density <= 24:
|
||||
"""Map VOCs µg/m3 to HomeKit AirQuality level.
|
||||
|
||||
The VOC mappings use the IAQ guidelines for Europe released by the WHO (World Health Organization).
|
||||
Referenced from Sensirion_Gas_Sensors_SGP3x_TVOC_Concept.pdf
|
||||
https://github.com/paulvha/svm30/blob/master/extras/Sensirion_Gas_Sensors_SGP3x_TVOC_Concept.pdf
|
||||
"""
|
||||
if density <= 250: # WHO IAQ 1 (HomeKit: Excellent)
|
||||
return 1
|
||||
if density <= 48:
|
||||
if density <= 500: # WHO IAQ 2 (HomeKit: Good)
|
||||
return 2
|
||||
if density <= 64:
|
||||
if density <= 1000: # WHO IAQ 3 (HomeKit: Fair)
|
||||
return 3
|
||||
if density <= 96:
|
||||
if density <= 3000: # WHO IAQ 4 (HomeKit: Inferior)
|
||||
return 4
|
||||
return 5
|
||||
return 5 # WHOA IAQ 5 (HomeKit: Poor)
|
||||
|
||||
|
||||